
Appendix E: Bench Configuration Testing
126
Assembling the Libra Units
Once you have assembled either one AP and one CPE (for P-MP) or a base and remote (for P-P) for
familiarization, you may use the AP or the Base to bench test any CPEs or remotes that may have
problems in the field. This setup can also be used to pre-configure units before field installation or to
pre-test units.
➧
To assemble Libra units
Details of the assembly of the Libra units are provided in the Description chapter (see
) and in the Field Installation chapter (see
Libra test network set-up
! CAUTION
Do not "hot plug" the power adapter into the Libra to power up the unit—the
Libra should first be plugged into the power inserter unit at the RJ-45 "TO
RADIO" connector. Next, the power inserter AC power supply cord should be
plugged into the AC outlet to power up the unit.
W orkstation
Hub
Computer
Sectoral Antenna
Access Point
Outdoor CAT-5
Cable
Power Inserter
CPE with
Integrated
Panel Antenna
Outdoor CAT-5
Cable
Power Inserter
Summary of Contents for LIBRA 5800 AP
Page 1: ...User Manual June 2003 Rev 0 Software Version 3 1...
Page 12: ...Notices 12 Libra 5800 Series User Guide...
Page 26: ...Description 26 Libra 5800 Series User Guide...
Page 44: ...Configuration 44 Libra 5800 Series User Guide...
Page 96: ...Field Installation 96 Libra 5800 Series User Guide...
Page 102: ...Troubleshooting 102 Libra 5800 Series User Guide...
Page 106: ...Appendix A Upgrading Software 106 Libra 5800 Series User Guide...
Page 116: ...Appendix B SNMP MIB 116 Libra 5800 Series User Guide...
Page 154: ...Menu Map 154 Libra 5800 Series User Guide...
Page 156: ...156 Libra 5800 Series User Guide...