XR3D-6 Maintenance & Troubleshooting
EM-XR3D-6-001-EN.D
3-11
©2011 VOTI Inc.
3.4.13 Save Test Results
To keep a soft copy of the ASTM scan information for your records, save the 2 test scans to a
USB key.
1. Put a USB external storage device in the USB slot at the Keypad.
2. Perform a scan and press
Send
.
The information currently on the screen is saved to the USB external storage device.
3.4.14 Sample ASTM Log Sheet
If the ASTM test does not pass, log off and contact the Administrator. An Administrator or VOTI-
certified technician logs on using Administrator permission to access the Windows
TM
desktop.
In the report to be sent back to VOTI, include the Low and High Sensitivity settings and the X-ray
Voltage and Current settings with the report to VOTI Support. For example, include the following
lines from the configuration file,
c:\Program Files\VOTI\cfg\Biosans.cfg
:
# Detector settings
...
int
highSensitivity = 12
int
lowSensitivity = 10
# X-Ray source settings
...
Int
xrsVoltage = 1600
Int
xrsCurrent = 900