Indicated on display
Possible cause of fault Possible effects
Fault remedy
05655/P1617
Glow period warning
lamp -K29-
Open circuit/short to
earth
◆
Wire open circuit or
wire has short to
earth
◆
-K29- defective
---
– Check -K29-
, final
control diagnosis
– Electrical test of pilot
line, connector or
lamp
05694/P163E
Control unit defective
◆
Internal defect in en-
gine control unit
-J623-
---
– -J623- Renew
05696/P1640
Control unit defective
◆
Internal defect in en-
gine control unit
-J623-
◆
ECU performs reset
– -J623- Renew
05778/P1692
Self-diagnosis warning
lamp -K83-
Short to earth
◆
Wire open circuit or
wire has short to
earth
---
– Check -K83-
, final
control diagnosis
– Check electrical con-
nection to lamp, if OK
=> lamp defective
flow diagrams
05779/P1693
Self-diagnosis warning
lamp -K83-
Short to positive
◆
Wiring open circuit or
wiring short to posi-
tive
---
– Check -K83-
, final
control diagnosis
– Check electrical con-
nection to lamp, if OK
=> lamp defective
flow diagrams
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
69