Indicated on display
Possible cause of fault Possible effects
Fault remedy
Implausible signal
◆
Open circuit or line
short-circuit
◆
Automatic glow peri-
od control unit -J179-
defective
◆
Entire glow plug sys-
tem does not work
◆
Engine does not start
or is difficult to start
when cold
◆
Possible smoke when
starting engine
– Check -J179-
, final
control diagnosis
– Check wiring to auto-
matic glow period con-
trol unit -J179-
flow diagrams
– Check terminal 30
fuse for glow plug
main circuit.
– Disconnect glow peri-
od control unit, and
measure voltage on
pin
– Check voltage on
wire.
01674/P068A
Main relay
Opens too early
◆
Open circuit or line
short-circuit
◆
Defective terminal 30
voltage supply relay
-J317-
◆
Engine stops
◆
Engine control unit
switched off
– Check wires to -J317-
flow diagrams
– Renew main relay, if
necessary
01675/P068B
Main relay
Opens too late
◆
Open circuit or line
short-circuit
◆
Defective terminal 30
voltage supply relay
-J317-
◆
Battery may be dis-
charged, because
ECU is not switched
off
– Check wires to -J317-
flow diagrams
– Renew main relay, if
necessary
01687/P0697
Sender reference voltage
“C”
Open circuit
◆
Open circuit or line
short-circuit
◆
Faults for sensors
connected to this
source are locked.
◆
Worst case - engine
stops
– Renewing engine con-
trol unit -J623-
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
63