cludes the ash deposit mass and the operating time of the die-
sel particulate filter. However, based on the mileage or the oper-
ating hours since the last change of the diesel particulate filter
this data can be restored approximately.
– Log in to the menu “015-Access permissions”.
– Select “Security Access”.
– This channel requires the access code 12233.
– Enter access code “12233”:
– Go back to the menu.
– To enter the mileage, go to “014-Long adaptation”.
– Select "Adaptation channel 15".
– Use the
Keypad
button to enter a hex value.
– Instead of the mileage (in 1000 km) the operating hours (x
0.06) may be entered as well. The result is the same.
Example: 1000 operating hours x 0.06 = 60 (entry in control
unit "0060") corresponds to 60,000 km.
– Confirm and save this value.
– Now the ash deposit mass has been recalculated and stored
(ignore error message).
– Select “Display group 108” “011-Read measured value
block”.
Indicated on display:
– Check condition of diesel particulate filter.
– Select “Display group 106” “011-Read measured value
block”.
Indicated on display:
– Check whether the adaptation value for the mileage is dis-
played which has been set beforehand.
– Exit diagnosis function.
– Store injector delivery calibration values/injector voltage cali-
bration values which have been read beforehand in engine
control unit
– Adapt exhaust gas pressure sensor 1 -G450-
– Then, read event memory of engine control unit, and clear
, read event memory.
Display group 108
110 ml 30.0 g 30.0 g
Display group 106
---- 0-60 0-1500 0-36000
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
466
Repair Group 26 - Exhaust system