Indicated on display
Possible cause of fault Possible effects
Fault remedy
Short to positive
◆
Wiring open circuit or
wiring short to posi-
tive
◆
Fuel pump relay -J49-
defective
◆
Engine control unit
-J623- defective
◆
Engine failure
– Pull off relay, and read
event memory again
– If in addition PSPOL--
> renew relay
– Otherwise, check wir-
ing between relay and
ECU
– Check wires between
-J49- and -J623-,
, current
flow diagrams
– If OK, renew control
unit.
01588/P0634
Control unit, temperature
shut-off
◆
Overload on output
stage(s) in -J623-
◆
Glow plug control
module is switched
off
◆
Very high ambient
temperature
◆
Engine control unit
not installed correctly
◆
Internal defect in en-
gine control unit
-J623-
◆
Possible smoke when
starting engine
◆
Entire glow plug sys-
tem does not work
◆
Possible bad cold
start behaviour of en-
gine
– -J623- Allow to cool
off, and clear event
memory
– If necessary, renew
ECU -J623-
01601/P0641
Sender reference voltage
“A”
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
56
Repair Group 01 - Vehicle self-diagnosis