Indicated on display
Possible cause of fault Possible effects
Fault remedy
00614/P0266
Incorrect injection quanti-
ty on cyl.2
◆
Adaption values do
not match adaption
value specified on in-
jector
◆
Glow period warning
lamp -K29- lights up
◆
Incorrect injection
quantity.
– Check injector deliv-
ery calibration values/
injector voltage cali-
bration values
– Adaption injector, if
adaptation is not pos-
sible, try to enter code
for injector delivery
calibration/injector
voltage calibration
from other injectors, if
adaptation still not
possible, ECU defec-
tive. If an additional
fault is stored, which
indicates a defective
EEProm --> renew
ECU
00617/P0269
Incorrect injection quanti-
ty on cyl.3
◆
Adaption values do
not match adaption
value specified on in-
jector
◆
Incorrect injection
quantity.
– Check injector deliv-
ery calibration values/
injector voltage cali-
bration values
– Adaption injector, if
adaptation is not pos-
sible, try to enter code
for injector delivery
calibration/injector
voltage calibration
from other injectors, if
adaptation still not
possible, ECU defec-
tive. If an additional
fault is stored, which
indicates a defective
EEProm --> renew
ECU
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
45