– Use hand-operated vacuum pump -VAS 6213- to generate a
partial vacuum of approx. -500 mbar.
If injector is OK, pressure remains constant for 30 s.
If injectors are defective, the pressure drops within 2 ... 3 s to 0
bar
Repeat check as necessary, observe pressure loss at hand vac-
uum pump -VAS 6213-.
1.10 Removing and installing injector (piezo injector)
Special tools and
workshop equipment
required
◆
Puller -T10055-
◆
Assembly sleeve
-T10377-
◆
Socket -T40055-
◆
Torque wrench
-V.A.G 1331-
◆
Ratchet -V.A.G 1331/1-
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
370
Repair Group 23 - Mixture preparation - injection