Indicated on display
Possible cause of fault Possible effects
Fault remedy
Electrical fault in current
circuit
◆
Open circuit or line
short-circuit
◆
-N18- defective
◆
No regeneration of
diesel particulate filter
◆
H bridge deactivated -
no EGR
◆
No limitation
– Check -N18-
control diagnosis
– Check wiring of DC
motor/EGR valve
(short-circuit between
M+ and M-)
– Disconnect EGR valve
--> clear event memo-
ry, fault stored again
== ECU defective -->
no new fault == actua-
tor defective
05121/P1401
Exhaust gas recirculation
valve
Short to earth
◆
Wire open circuit or
wire has short to
earth
◆
-N18- defective
◆
No exhaust gas recir-
culation
◆
H bridge deactivated
◆
No regeneration of
diesel particulate filter
◆
No limitation
– Check -N18-
control diagnosis
– Check wiring of DC
motor/EGR valve
(short-circuit between
M+ and M-)
– Disconnect EGR valve
--> clear event memo-
ry, fault stored again
== ECU defective -->
no new fault == actua-
tor defective
05122/P1402
Exhaust gas recirculation
valve
Short to positive
◆
Open circuit or short
to positive in wire
◆
-N18- defective
◆
No exhaust gas recir-
culation
◆
H bridge deactivated
◆
No regeneration of
diesel particulate filter
◆
No limitation
– Check -N18-
control diagnosis
– Check wiring of DC
motor/EGR valve
(short-circuit between
M+ and M-)
– Disconnect EGR valve
--> clear event memo-
ry, fault stored again
== ECU defective -->
no new fault == actua-
tor defective
05184/P1440
Exhaust gas recirculation
valve
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
66
Repair Group 01 - Vehicle self-diagnosis