Indicated on display
Possible cause of fault Possible effects
Fault remedy
Electrical fault
◆
Open circuit or line
short-circuit
◆
-N290- defective
◆
Failure of metering
unit
– Check fuel metering
valve -N290-
– Check electrical con-
nection to metering
unit
– Check terminal 15 ON
and +12V on actuator
+ (A2). No voltage
⇒
open circuit between
Vbat and actuator
– Pull connector off ac-
tuator, and check wir-
ing between actuator/
ECU
– Measure resistance
on actuator. If no con-
tinuity
⇒
renew ECU
00145/P0091
Fuel metering valve
-N290-
Short to earth
◆
Wiring short to earth
◆
-N290- defective
◆
Failure of metering
unit and engine
– Check fuel metering
valve -N290-
– Pull connector off ac-
tuator, and read event
memory again. If in
addition MeUnOL
⇒
renew actuator - oth-
erwise check wiring
between actuator/
ECU - if OK
⇒
renew
ECU
00146/P0092
Fuel metering valve
-N290-
Short to positive
◆
Wire has short to
positive
◆
-N290- defective
◆
Failure of metering
unit
– Check fuel metering
valve -N290-
– Pull connector off ac-
tuator, and read event
memory again. If in
addition MeUnOL
⇒
renew actuator - oth-
erwise check wiring
between actuator/
ECU - if OK
⇒
renew
ECU
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
33