TEST MODES AND TROUBLESHOOTING: Error Messages in GP-GL Command Mode
9-10
9.6 Error Messages in GP-GL Command Mode
Symptom Cause
Solution
ERROR 1
COMMAND ERROR
The plotter received an unrecognizable
command.
• Noise was input to the plotter upon
execution of the software application.
Press the ENTER key.
• The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 4
PARAMETER
OVERFLOW
A command was received containing
numeric parameters that exceed that
command's permissible range.
• The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 5
I/O ERROR
An error occured in the receipt of data
within the interface.
• The software command settings for
connecting changed,
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
Summary of Contents for Q100
Page 34: ...Cutter Blades and Cutter Pens Adjusting the Blade Length 2 6 ...
Page 64: ...Pen Setting Conditions Adjusting the Blade Length 4 12 ...
Page 140: ...ADVANCED FUNCTIONS AND OPERATIONS Selecting the Type of Perforated Line 6 62 ...
Page 148: ...OPTIONS Pen Offset for 2 pen models only 7 8 ...
Page 174: ...INTERFACES COMMAND Settings 10 8 ...