Specifications, Chapter 3 - Specifications
Measurement
5
, Power (1030 AND 1090 MHz)
1-3-1
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 12
Subject to Export Control. See Cover Page for details.
September 2021
6.
MEASUREMENT
5
6.1
POWER (1030 AND 1090 MHZ)
Range:
+17 to +60 dBm
Resolution:
0.1dB
Accuracy:
0.5 dB
6.2
FREQUENCY
Pulse Measurement Type:
Range:
1030 MHz:
3 MHz
1090 MHz:
3 MHz
Resolution:
1 KHz
Accuracy:
50 KHz
Frequency 1030 Measurement Type (TCAS, DO-186, Mode S, Test-Mode 3 only):
Range:
1030 MHz (
50 KHz)
Resolution:
100 Hz
Accuracy:
1 KHz
6.3
PHASE (TCAS)
Range:
0 to 359° (any Port relative to T1/B1)
Resolution:
1°
Accuracy:
4°
6.4
PULSE SPACING
Resolution:
1 ns
Accuracy:
10 ns
6.5
PULSE WIDTH
Resolution:
1 ns
Accuracy:
15 ns
6.6
PULSE RISE/FALL TIME
Resolution:
1 ns
Accuracy:
15 ns
6.7
REPLY DELAY (XPDR)
Resolution:
25 ns
Accuracy:
50 ns