Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 188
Subject to Export Control. See Cover Page for details.
September 2021
5.12.7
RESET
5.12.8
SERIAL NUMBER REQUEST
5.12.9
SOFTWARE VERSION REQUEST
5.12.10
UNIT NAME
Command Syntax:
{:RGS | :RGS2000NG}{:RESET}CR
Description:
This command executes a global reset to the Unit. This global reset
includes the following tasks:
1. Stop any execution.
2. Reset RTCA/DO-260 Test.
3. Reset Block Transmission Test.
4. Reset Transponder Test.
5. Reset Own Aircraft Position. Set the Own Aircraft Latitude, Longitude,
Heading and Altitude to zero. Set the Own Aircraft Mode S Address to 4.
6. Reset Scenario.
7. Sets the Unit to the factory default settings.
Return:
”*” is returned if the factory settings were able to complete successfully.
“?” is returned if a failure occurs.
Example:
:RGS:RESET\r
NOTE:
This command takes approximately 10 seconds to complete before returning
the asterisk.
Command Syntax:
{:RGS |:RGS2000NG}{:SN?}CR
Description:
This command returns the serial number of the unit.
Return Value:
ASCII value.
Example:
:RGS:SN?\r
Return:
10000000002
Command Syntax:
{:RGS |:RGS2000NG}{:SW?}CR
Description:
This command returns the software version of the unit.
Return Value:
Hexadecimal value.
Example:
:RGS:SW?\r
Return:
1A
Command Syntax:
{:RGS | :RGS2000NG}{:NAME?}CR
Description:
This command returns the Unit name.
Return Value:
ASCII value.
Example:
:RGS:NAME?\r
Returns:
RGSSN10000000002