Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 53
5.9.4.2.1.10
Horizontal Reference Direction
5.9.4.2.1.11
Ident Switch Active
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | : DYN: | :
DYNAMIC:}<intruder number>{:SAOS}{:HRD}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter
horizontal reference direction field to the specified value.
Numeric:
0 to 1 (decimal ASCII)
Value
Meaning
0
True North
1
Magnetic North
Default:
0
Example:
:RGS:SCE:DYN:1:SAOS:HRD 1\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | : DYN: | :
DYNAMIC:}<intruder number>{:SAOS}{:IDT}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter
IDENT switch active field to the specified value.
Numeric:
0 to 1 (decimal ASCII)
Value
Meaning
0
IDENT not active
1
Set for 18 seconds after IDENT switch is pressed.
Default:
0
Example:
:RGS:SCE:DYN:1:SAOS:IDT 1\r