5.10.5
RECEIVER PATH
Command Syntax:
{:RGS | :RGS2000NG}{:SET | :SETTINGS}{:RCV | :RCVR}{:PA |
:PATH}SP<numeric>CR
Description:
This command sets the receiver path for the top and bottom receiver to the
channel represented by the numeric value. Chamber is selected when the
Unit is working with an RF Amplifier (Chamber) Test Set option. The RF
Amplifier (Chamber) directs the receive port to T1 and 30 dB of attenuation
is removed from the Unit T1 path. Combiner is used to receive messages
from the UUT when testing a magnitude TCAS system.
Numeric:
0 to 5 (decimal ASCII)
Value
Channel
0
T1/B1
1
T2/B2
2
T3/B3
3
T4/B4
4
Chamber
5
Combiner
Return:
”*” is returned if the command was able to complete successfully
“?” if a failure occurs.
Default:
T1/B1
Example:
:RGS:SET:RCV:PA 0\r