Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 200
Subject to Export Control. See Cover Page for details.
September 2021
5.13.2.2
DO-260 Test Dual ADS-B
The following example creates a test of type normal for a dual ADS-B.
//BEGIN TEST
//RESET DO260 TEST
:RGS:DO260:RESET
//TEST DEFINITION
//TIMING DEFINTION
:RGS:DO260:TIMING:TRIGGER:SOURCE GENA
//0-DELAY+ 1-DELAY- 2-RANDOM
:RGS:DO260:TIMING:TRIGGER:MODE 0
:RGS:DO260:TIMING:PERIOD 10
//0-UNLIMITED
:RGS:DO260:TIMING:TRANSMISSIONS 0
//SPECIAL TYPE DEFINITION
:RGS:DO260:TYPE:NORMAL:GENS:GENA:POWER -20
:RGS:DO260:TYPE:NORMAL:GENS:GENA:PHASE 0
:RGS:DO260:TYPE:NORMAL:GENS:GENA:PATH TOP
//:RGS:DO260:TYPE:NORMAL:GENS:GENA:DELAY 0 //Not Available for Gen A. Business Rule's
:RGS:DO260:TYPE:NORMAL:GENS:GENA:SIGNAL ON
:RGS:DO260:TYPE:NORMAL:GENS:GENA:MODES:DATA 8800000148000000000000000001
:RGS:DO260:TYPE:NORMAL:GENS:GENA:MODES:RANDOM OFF
:RGS:DO260:TYPE:NORMAL:GENS:GENB:POWER -30
:RGS:DO260:TYPE:NORMAL:GENS:GENB:PHASE 0
:RGS:DO260:TYPE:NORMAL:GENS:GENB:PATH TOP
:RGS:DO260:TYPE:NORMAL:GENS:GENB:DELAY 0
:RGS:DO260:TYPE:NORMAL:GENS:GENB:SIGNAL ON
:RGS:DO260:TYPE:NORMAL:GENS:GENB:MODES:DATA 8800000148000000000000000001
:RGS:DO260:TYPE:NORMAL:GENS:GENB:MODES:RANDOM OFF
//BEGIN DO260 TEST
:RGS:DO260:START
//END OF TEST.