5.9.4.5.6
Reply Quadrant Criteria 2
5.9.4.6
BDS Reply Parameters
Each Mode S intruder (target) can have up to eight (8) BDS registers defined. Position, Identification
and Velocity are already available.
5.9.4.6.1
BDS Reply
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder
number>{:WS2:}<wslevel>{:RPLYQUAD}SP{FORWARD | RIGHT | LEFT |
AFTER | OMNI | LOCATION }CR
Description:
This command sets the reply criteria for whisper shout level 2 of an
ATCRBS intruder. Whisper shout level is a number between 0 and 255. The
reply quadrant can be forward, right, left, after, Omni (any quadrant) or
location (reference to own aircraft bearing).
Numeric:
wslevel = 0 to FF (hexadecimal ASCII characters)
Default:
Whisper/Shout 0, Forward
Example:
:RGS:SCE:STAT:2:WS2:81:RPLYQUAD RIGHT\r
NOTE:
This command is only used for ATCRBS intruders.
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:STAT: | :STATIC: | :DYN: |
:DYNAMIC:}<intruder number>{:BDS:}<bds numeric>{:MESS | :MESSAGE}
SP<numeric>CR
Description:
This command sets the BDS reply for the selected intruder.
Numeric:
bds numeric: 0 to FF (2 hexadecimal ASCII characters). Except the default
register numbers (5, 6, 8, 9, 62, and 65).
numeric: 0 to FFFFFFFFFFFFFF (14 hexadecimal ASCII characters)
Example:
:RGS:SCE:STAT:2:BDS:3:MESS 1234FA2796BCA1\r