Operation,
Operating Procedures and Test Configurations
1-2-4
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 2
Subject to Export Control. See Cover Page for details.
September 2021
4.1
OPERATING PROCEDURES
4.1.1
CONFIGURE STATIC IP NETWORK CONNECTION
NOTE:
USERS SHOULD CONTACT THE IR IT DEPARTMENT T O ENSURE THE STATI C IP
ADDRESS BEING ASSIGNED TO THE TEST SE T I S NO T ALREA D Y IN US E ON THE
NETWORK. ASSIGNING A STATIC IP ADDRESS TO THE TES T SET IF THE IP
ADDRESS IS ALREADY IN USE BY ANO THER DE VI CE ON TH E NE TWOR K WI LL
CAUSE A NETWORK CONFLICT.
STEP
PROCEDURE
1
Go to the
H o m e S c r e e n
.
2
Connect an active Ethernet cable to the test Set’s Front or Rear Panel LAN Connector.
3
Navigate to the
N e t w o r k C o n n e c t i o n s
Screen.
4
Select the LAN Connector from the Network Connection Table.
5
Select the
C h a n g e S e t t i n g s
Softkey.
6
Select the
U s e t h e f o l l o w i n g I P A d d r e s s
Tick Box.
7
Enter the IP Address, Subnet Mask and Gateway fields according to network settings.
8
Select the
S e t
Softkey to initialize the network settings.
4.1.2
CONFIGURE DHCP NETWORK CONNECTION
STEP
PROCEDURE
1
Go to the
H o m e S c r e e n
.
2
Connect an active Ethernet cable to the test Set’s Front or Rear Panel LAN Connector.
3
Navigate to the
N e t w o r k C o n n e c t i o n s
Screen.
4
Select the LAN Connector from the Network Connection Table.
5
Select the
C h a n g e S e t t i n g s
Softkey.
6
Select the
O b t a i n a n I P A d d r e s s a u t o m a t i c a l l y
Tick Box.
7
Select the
S e t
Softkey to initialize the network settings.
8
Wait while the server configures the Test Set’s network connection.
4.1.3
RESTORE TEST SET’S INTERNAL IP ADDRESS
NOTE:
THE TEST SET’S INTERNAL IP ADDRESS SHOULD NOT BE CHANGED. IN T HE
EVENT THE TEST S ET’S INTERNAL IP ADDRESS I S CHANGED IN ERROR, US E TH I S
PROCEDURE TO RESTORE THE INTERNAL I P ADDRESS TO THE DEFAUL T SETT IN G
(192.168.0.1).
STEP
PROCEDURE
1
Go to the
H o m e S c r e e n
.
2
Navigate to the
N e t w o r k C o n n e c t i o n s
Screen.
3
Select the Internal Connector from the Network Connection Table.
4
Select the
C h a n g e S e t t i n g s
Softkey.
5
Select the
U s e t h e f o l l o w i n g I P A d d r e s s
Tick Box.
6
Enter the IP address for the internal DSP connection.
7
Select the
S e t
Softkey.
8
Wait while the Test Set reconfigures the internal DSP settings. When this process is complete,
the system resets the connection and reboots the DSP. This process takes a few minutes.
9
When this process is complete the application software re-establishes internal communications
with the DSP using the new IP Address. On all future reboots the new IP address is used.