Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 11
5.4.3
MESSAGE PARAMETERS
5.4.3.1
Data
5.4.3.2
Phase
5.4.3.3
Power Level
Command Syntax:
{:RGS | :RGS2000NG}{:TXBLOCK:}<message number> {:MESS |
:MESSAGE}SP<numeric>CR
Description:
This command sets the data message for the message selected.
Message Number:
1 to 1000
Numeric:
Short message 0 to FFFFFFFFFFFFFF (14 hexadecimal ASCII)
Long message 0 to FFFFFFFFFFFFFFFFFFFFFFFFFFFF (28 hexadecimal
ASCII)
The last six characters are the Mode S Address.
ATCRBS Reply 0 to FFF(3 hexadecimal ASCII)
Default:
Mode S Interrogation | Mode S Message: 00000000000001
ATCRBS Reply. : 000
Example:
:RGS:TXBLOCK:1:MESS ACBDEF12345678\r
Command Syntax:
{:RGS | :RGS2000NG}{:TXBLOCK:}<message number>{:PHASE | :PHA
}SP<numeric>CR
Description:
This command sets the phase of the message selected.
Message Number:
1 to 1000
Numeric:
0 to 359 (decimal ASCII)
Default:
0
Example:
:RGS:TXBLOCK:2:PHA 45\r
Command Syntax:
{:RGS | :RGS2000NG}{:TXBLOCK:}<message number>{:POWER |
:POW}SP<numeric>CR
Description:
This command sets the power level of the message selected.
Message Number:
1 to 1000
Numeric:
High Power Mode: 1 to -69 dBm (decimal ASCII)
Low Power Mode: -20 to -90 dBm (decimal ASCII)
Default:
-20 dBm
Example:
:RGS:TXBLOCK:1:POW -22\r