Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 12
Subject to Export Control. See Cover Page for details.
September 2021
5.4.3.4
Time
5.4.3.5
Type
Command Syntax:
{:RGS | :RGS2000NG}{:TXBLOCK:}<message number>{:TIME
}SP<numeric>CR
Description:
This command sets the starting transmission time (in µs) within the block of
the message selected.
Message Number:
1 to 1000
Numeric:
0 to 89999880 (decimal ASCII)
Default:
0 µs.
Every additional message defaults 130 µs after previous. Maximum time
depends on frame period value.
Example:
:RGS:TXBLOCK:2:TIME 99\r
Command Syntax:
{:RGS | :RGS2000NG}{:TXBLOCK:}<message
number>{:TYPE}SP<numeric>[,<numeric1>]CR
Description:
This command sets the type of the message selected. The optional
argument <numeric1> defines the ATCRBS Interrogation type.
Message Number:
1 to 1000
Numeric:
1 to 4 (decimal ASCII)
Value
Type
1
Mode S Interrogation
2
ATCRBS Interrogation
3
Mode S Message.
4
ATCRBS Reply.
Default:
Mode S Message
Numeric1:
1 to 6 (decimal ASCII)
Valid only if the type of message defined in <Numeric> is ATCRBS
Interrogation.
Value
Type
1
Mode A
2
Mode C
3
Mode A Only All Call
4
Mode C Only All Call
5
Mode A/Mode S All Call
6
Mode C/Mode S All Call
Default:
Mode A
Example:
:RGS:TXBLOCK:1:TYPE 2,1\r