Operation,
Screen Layout and Navigation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-3
September 2021
Subject to Export Control. See Cover Page for details.
Page 193
Offset Field
Defines the offset or delay of the intruder.
If Manual Override is enabled, the calculated Offset is replaced
by the defined Offset.
If Manual Override is disabled, the Offset is calculated between
the Target Latitude and Longitude and the Receiving Station
Latitude and Longitude.
Manual Override Tick Box
Allows the user to select the enable the Offset Manual Override.
FEC Calculator Softkey
Pressing this softkey calculates the Forward Error Correction.
Squitter Power Field
Defines the Squitter Power.
Screen Components
Descriptio n