Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 177
5.11.17.3.8
Table Entry Mode S Interrogation Message Data
5.11.17.3.9
Table Entry Pulse Power Level
Command Syntax:
{:RGS | :RGS2000NG}{:XPDR}{:ITABLE:}<table entry>{:UF}SP<numeric>CR
Description:
This command sets the data message for the Mode S Interrogation of the
selected table entry.
Table Entry:
1 to 32 (decimal ASCII)
Numeric:
Short interrogation 0 to FFFFFFFFFFFFFF (14 hexadecimal ASCII)
Long interrogation 0 to FFFFFFFFFFFFFFFFFFFFFFFFFFFF ( 28
hexadecimal ASCII). The last six characters are the Mode S Address.
Default:
00000000000001
Example:
:RGS:XPDR:ITABLE:1:UF 123456789ABCDE\r
Query:
:RGS:XPDR:ITABLE:1:UF?\r
Returns:
123456789ABCDE
Command Syntax:
{:RGS |:RGS2000NG}{:XPDR}{:ITABLE:}<table entry>{:POW
|:POWER}SP<numeric>CR
Description:
This command sets the antenna power for the top antenna of the table entry
selected.
Table Entry:
1 to 1000 (decimal ASCII)
Numeric:
-90 TO -20 dBm (decimal ASCII)
Default:
-20 dBm
Example:
:RGS:XPDR:ITABLE:1:POW -31\r
Query:
:RGS:XPDR:ITABLE:1:POW?\r
Return:
-31.0
NOTE:
The power level range depends of the power mode selected using the
previous command.