Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 45
5.9.3.5
Interval Start Time
5.9.3.6
Interval Stop Time
5.9.3.7
Quantity
5.9.3.8
Start Time
5.9.3.9
Stop Time
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:INTER: | :INTERROGATOR:}
<interrogator number>{:INT: | :INTERVAL:}<interval
number>{:BEGIN}SP<numeric>CR
Description:
This command sets the start time for the selected interrogation interval.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
0
Example:
:RGS:SCE:INTER:2:INT:4:BEGIN 0.4\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:INTER: |
:INTERROGATOR:}<interrogator number>{:INT: | :INTERVAL:}<interval
number>{:END }SP<numeric>CR
Description:
This command sets the stop time for the selected interrogation interval.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
Scenario stop time
Example:
:RGS:SCE:INTER:2:INT:4:END 0.5\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:INTER |
:INTERROGATOR}{:QUAN | :QUANTITY}SP<numeric>CR
Description:
This command sets the number of interrogators (ground stations).
Numeric:
0 to 15 (decimal ASCII)
Example:
:RGS:SCE:INTER:QUAN 3\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:INTER: | :INTERROGATOR:}
<interrogator number>{:BEGIN}SP<numeric>CR
Description:
This command sets the start time for the selected interrogator.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
0
Example:
:RGS:SCE:INTER:2:BEGIN 2\r
Command Syntax:
{:RGS | :RGS2000NG}{:SCE | :SCENARIO}{:INTER: | :INTERROGATOR:}
<interrogator number>{:END}SP<numeric>CR
Description:
This command sets the stop time for the selected interrogator.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
Scenario time
Example:
:RGS:SCE:INTER:2:END 2.6\r