Operation,
Remote Operation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-5
September 2021
Subject to Export Control. See Cover Page for details.
Page 203
5.13.2.5
DO-260 Special Test Altered Preamble
The following example creates a special test for an ADS-B altered preamble.
//BEGIN TEST
//RESET DO260 TEST
:RGS:DO260:RESET
//TEST DEFINITION
//TIMING DEFINTION
:RGS:DO260:TIMING:TRIGGER:SOURCE GENA
//0-DELAY+ 1-DELAY- 2-RANDOM
:RGS:DO260:TIMING:TRIGGER:MODE 0
:RGS:DO260:TIMING:PERIOD 10
//0-UNLIMITED
:RGS:DO260:TIMING:TRANSMISSIONS 0
//SPECIAL TYPE DEFINITION
:RGS:DO260:TYPE:ALTEREDPREAMBLE:PULSE:P1:WIDTH 500
:RGS:DO260:TYPE:ALT:PULSE:P1:POSITION 0
:RGS:DO260:TYPE:ALTEREDPREAMBLE:PULSE:P1:REFERENCE GENA
:RGS:DO260:TYPE:ALT:PULSE:P1:ENABLE ON
:RGS:DO260:TYPE:ALT:PULSE:P2:WIDTH 500
:RGS:DO260:TYPE:ALT:PULSE:P2:POSITION 1000
:RGS:DO260:TYPE:ALT:PULSE:P2:REFERENCE GENA
:RGS:DO260:TYPE:ALT:PULSE:P2:ENABLE ON
:RGS:DO260:TYPE:ALT:PULSE:P3:WIDTH 500
:RGS:DO260:TYPE:ALT:PULSE:P3:POSITION 3500
:RGS:DO260:TYPE:ALT:PULSE:P3:REFERENCE GENA
:RGS:DO260:TYPE:ALT:PULSE:P3:ENABLE ON
:RGS:DO260:TYPE:ALT:PULSE:P4:WIDTH 500
:RGS:DO260:TYPE:ALT:PULSE:P4:POSITION 4500
:RGS:DO260:TYPE:ALT:PULSE:P4:REFERENCE GENA
:RGS:DO260:TYPE:ALT:PULSE:P4:ENABLE ON
:RGS:DO260:TYPE:ALTEREDPREAMBLE:GENS:GENA:POWER -20
:RGS:DO260:TYPE:ALT:GENS:GENA:PHASE 0
:RGS:DO260:TYPE:ALT:GENS:GENA:PATH TOP
//:RGS:DO260:TYPE:ALT:GENS:GENA:DELAY 0 //Not Available for Gen A. Business Rule's
//:RGS:DO260:TYPE:ALT:GENS:GENA:SIGNAL ON //Not Available for Special Test. Business Rule's
:RGS:DO260:TYPE:ALT:GENS:GENA:MODES:DATA 8800000148000000000000000001
//:RGS:DO260:TYPE:ALT:GENS:GENA:MODES:RANDOM OFF //Not Available for Special test. Business
Rule's
:RGS:DO260:TYPE:ALT:GENS:GENC:POWER -20
:RGS:DO260:TYPE:ALT:GENS:GENC:PHASE 0