Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
459
Function Code 7B5:
(Continued)
Typical Response Message, Computer Format:
<SOH>i7B5TTYYMMDDHHmmTTpPPRRYYMMDDHHmmNNFFFFFFFF...
TTpPPRRYYMMDDHHmmNNFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal)
3.
p - Product Code (one ASCII character [20h-7Eh])
4.
PP - Probe type (Decimal)
5.
RR - Result code - if an error occurs, just error code will be
returned (Decimal)
00=OK and data will follow
01=BIR not enabled
02=Tank number is invalid
03=missing time/date
04=Time Date not numeric
05=invalid date
06=time is invalid
07=Date out of range of period (curr & prev via BIR)
08=If there is no matching time/date for edit
09=Invalid volume
10=Try to insert when gauged exists
30=Reserved
31=Reserved
6.
YYMMDDHHmm - Delivery Date/Time (End Time)
7.
NN - Number of eight character Data Fields to follow (Hex)
8.
FFFFFFFF - ASCII Hex IEEE floats:
1. Ticketed volume
2. Gauged volume
3. Delivery variance
9.
&& - Data Termination Flag
10.
CCCC - Message Checksum