317
Function Code:
628
Version 1
Function Type:
Set Tank Maximum Volume Limit
Command Format:
Inquire:
Display:
<SOH>S628TTGGGGGG
<SOH>I628TT
Computer:
<SOH>s628TTFFFFFFFF
<SOH>i628TT
Notes:
1.
TT - Tank Number (Decimal, 00=all)
2.
GGGGGG - Maximum Volume Limit, Gallons (Decimal)
3.
FFFFFFFF - Maximum Volume Limit, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I628TT
JAN 22, 1996 3:19 PM
TANK MAXIMUM VOLUME LIMIT
TANK LABEL GALLONS
1 REGULAR UNLEADED 9600
<ETX>
Typical Response Message, Computer Format:
<SOH>i628TTYYMMDDHHmmTTFFFFFFFF...
TTFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=all)
3.
FFFFFFFF - Maximum Volume Limit, Gallons (ASCII Hex IEEE float)
4.
&& - Data Termination Flag
5.
CCCC - Message Checksum