Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
453
Function Code:
79P
Version 2
Function Type:
Set Meter Calibration Offset by Meter
Command Format:
Inquire:
Display:
<SOH>S79P00 Bxx.Sx FP MM 0.0000
<SOH>I79P00
<SOH>S79P00 Cxx FP MM 0.0000
<SOH>I79P00
Computer:
<SOH>s79H00 Bxx.Sx FP MM FFFFFFFF
<SOH>i79P00
<SOH>s79H00 Cxx FP MM FFFFFFFF
<SOH>i79P00
Notes:
1.
Bxx.Sx - VR BUS and Slot
Cxx - Comm Slot
2.
FP - Real fueling position number (Decimal)
3.
MM - Real meter number (Decimal)
Typical Response Message, Display Format:
<SOH>
I79P00
JAN 22, 2009 3:24 PM
SOURCE REAL REAL CALIBRATION
ADDRESS FP METER OFFSET
B1.S2 00 00 0.0000
B1.S2 00 01 0.0000
B1.S2 00 03 0.0000
COMM 2 01 00 0.0000
<ETX>
Typical Response Message, Computer Format:
<SOH>i79P00YYMMDDHHmm Bxx.Sx FP MM FFFF...
Cxx FP MM FFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
Bxx.Sx - VR BUS and Slot
Cxx - Comm Slot
3.
FP - Real Fueling Position number (Decimal)
4.
MM - Real meter number
5.
FFFFFFFF - Calibration Offset (-9.99 thru 9.99) ASCII Hex IEEE float
6.
&& - Data Termination Flag
7.
CCCC - Message Checksum