If neither light is lit, the main power emergency button status is OFF.
•
If the green light is lit, the main power emergency button status is ON.
•
If the green light is blinking, the main power is shutting down with the delay.
•
If the red light is blinking, the red button has been pressed while the ignition
has been in the OFF position and the main power shuts down after the delay.
This is an unlikely situation as the main power emergency button is controlled
automatically by the ignition switch.
•
If the red light is lit, the red button has been pressed while driving and the
main power shuts down after the delay once the ignition has been turned to
the OFF position. This is an unlikely situation as the main power emergency
button is controlled automatically by the ignition switch.
1. Turn the ignition to the
(OFF) position and remove the key from the
ignition switch.
2. Open the cover of the electric centre.
3. Press the red button of the main power emergency button for three seconds.
The main power is switched off without a delay and the red light is lit in the
main power emergency button to indicate that the power is off.
NOTE: The electric system does not save data or perform controlled
shutdown and the urea lines will not be emptied.
4. Reset the main power emergency shutdown in either of the two ways.
•
Press the green button of the main power emergency button.
•
Disconnect a battery cable terminal.
3.2.19
Using the roof hatch
1
GUID-49C3C0CD-044D-4E66-8D04-35A192DE63FE
1. Handle
3. Operation
- 86 -
Summary of Contents for Versu N Series
Page 1: ...OPERATOR SMANUAL NSERIES Versu Ref no 39 893 21 3 08 2015 YOUR WORKING MACHINE...
Page 2: ......
Page 517: ......