7-6
Valco Melton
Section 7 – Maintenance
MM125 - D-90 Hot Melt Unit
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
If the system is hot, wear insulated gloves
and eye protection when disconnecting
hoses. Failure to observe could result in
personal injury, death, or damage to
equipment.
11. Turn the pump off.
12. Turn on the heating zones for the applicators.
13. Allow the applicators to reach temperature.
14. Reconnect the glue hoses to the applicators/units.
15. Turn the pump back on and activate the applicators to purge
remaining adhesive through the valve(s).
16. Reset the temperature control to the correct setting for the
material you are using.
The new material can now be pumped
through the system.
Parts
Replacement
Flushing the System - Continued
5.
Manually activate the applicators to relieve any system pressure
buildup if the system is hot (if applicable).
6.
Disconnect glue hoses from applicators/unit, and collect purged
material with an appropriate container.
7.
Turn off the heating zone for the applicators.
8.
Allow the unit and hoses to reach temperature.
9.
Turn the pump on.
10. Pump purge material through the unit and glue hoses until
discharged material is free of particles.
Occasionally, parts may need to be repaired or replaced. The following
paragraphs contain instructions for removing parts from the hot melt unit. For
drawings and a complete list of part numbers, see
Section 10 — Part Number
List.
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...