APPENDIX B - POWER REQUIREMENTS
APPENDIX B - POWER REQUIREMENTS
APPENDIX B - POWER REQUIREMENTS
APPENDIX B - POWER REQUIREMENTS
APPENDIX B - POWER REQUIREMENTS
System Power
Requirement
Calculation -
D-90 Units
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Calculate all power requirements, as stated below,
before hooking up power. OTHERWISE, DEATH OR
SEVERE INJURY AND DAMAGE TO EQUIPMENT
AND/OR THE CIRCUIT COULD OCCUR.
For incoming power requirements, see
Section 4 -
Installation.
Power requirements for the D-90 System (unit, hoses
and guns) must be calculated before hooking up power,
to verify that the hoses and guns do not exceed the
power rating for the unit. Personnel injury, as well as
serious equipment damage, can result from overloading
the system.
This calculation will depend on the following two factors:
·
The wattage for any hose/gun pair
·
The total wattage for all hoses and guns
Perform the system power requirement calculation for the
D-90
unit as follows,
referring to Table 1, below:
1.
Add the power requirements of hose #1 and gun #1. Compare
this value to the maximum wattage given in Line 1 of Table 1.
2.
Add the power requirements of hose #2 and gun #2. Compare
this value to the maximum wattage given in Line 2 of Table 1.
3.
Add the power requirements of hose #3 and gun #3. Compare
this value to the maximum wattage given in Line 3 of Table 1.
4.
Add the power requirements of hose #4 and gun #4. Compare
this value to the maximum wattage given in Line 4 of Table 1.
5.
Add the power requirements of hose #5 and gun #5. Compare
this value to the maximum wattage given in Line 5 of Table 1.
Table 1. Maximum Allowable Wattage for the D-90 Series Unit
Table 1. Maximum Allowable Wattage for the D-90 Series Unit
Table 1. Maximum Allowable Wattage for the D-90 Series Unit
Table 1. Maximum Allowable Wattage for the D-90 Series Unit
Table 1. Maximum Allowable Wattage for the D-90 Series Unit
Line
Description
Maximum
Wattage (W)
1
Total for hose/gun 1 pair
2300
2
Total for hose/gun 2 pair
2300
3
Total for hose/gun 3 pair
1400
4
Total for hose/gun 4 pair
1400
5
Total for hose/gun 5 pair
1400
6
Total for hose/gun 6 pair
1400
7
Total for all hoses and guns
8600
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...