9-1
Valco Cincinnati, Inc.
SECTION 9 - SPECIFICATIONS
SECTION 9 - SPECIFICATIONS
SECTION 9 - SPECIFICATIONS
SECTION 9 - SPECIFICATIONS
SECTION 9 - SPECIFICATIONS
General
It is the purchaser’s responsibility to ensure that all local, county, state, and
national codes, regulations, rules, and laws relating to safety and safe
operating conditions are met and followed.
#
Weight (maximum) includes the unit with all options installed, coupled with
the weight of the crate.
* Test run with standard adhesive at 10,000 cPs. Melt rate will vary with input
voltage and adhesive.
** Pump rate based on a motor speed of 100 rpm and material with a specific
gravity of 1.0.
Height
53 inches (1,346 mm)
Width
30 inches (762 mm)
Depth
41 inches (1041 mm)
Tank Capacity
90 kg (200lb)
Drop-In Grid
Standard
Melt Rate
100 kg/hr (220 lb/hr)
Gear Pump
0.7 lb/hr (0.3 kg/hr) - 41 lb/hr (19 kg/hr)
1.4 lb/hr (0.6 kg/hr) - 85 lb/hr (39 kg/hr)
3 lb/hr (1.3 kg/hr) - 170 lb/hr (77 kg/hr)
6 lb/hr (2.5 kg/hr) - 334 lb/hr (152 kg/hr)
Gear Pump Control
A.C. with line-tracking feature for variable speeds
Number of Pumps
1-2
Number of Hoses/Guns
1-6
Hose Fittings
#6 (3/8"), #8 (1/2"), #12 (3/4") and #16 (1") options
Pressure Safety Relief
Manual relief with internal safety relief
Pneumatic relief with manual relief
Uniflow 12V with manual relief
Uniflow 24V with manual relief
Temperature Control
UTC-20 Microprocessor PID 16-Zone capable
Voltage
380, 400, 440, 480, 575, 595 VAC, 3PH, 50/60 Hz
Level Sensors
Optional Low and High Level Sensors
Pressure Monitor
Optional
Applications
Profile Wrapping, Laminating, Book Binding
SPECIFICATIONS
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...