Section 4 - Installation
MM125 - D-90 Hot Melt Unit
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Never disconnect the hot melt hoses from a running unit.
Hot melt is under high pressure. Turn off the pump, shut
off power to the unit, and actuate the gun to relieve
residual pressure before removing the hose. Failure to
observe could result in personal injury, death, or
damage to equipment.
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
Do not operate the unit with the fluid outlet ports open to
the air. Failure to observe could result in personal injury,
death, or damage to equipment.
When routing and installing heated hoses, follow these guidelines:
•
Avoid creating sharp corners and edges.
•
Do not bend hoses sharper than 18" (460 mm) radius.
•
Do not group heated hoses so that they contact one another.
•
Avoid positioning hoses where they can be stepped on or have a
chance of being crushed or cut.
•
Avoid the use of unnecessarily long hoses where the hose is
looped or curled on the floor. Excess twisting of the hose can
cause irreparable damage to it.
•
Maintain separation between hoses to avoid hot spots.
To connect the hot melt hoses to the unit, follow these steps:
1.
Using a pair of wrenches, one on the fluid outlet fitting and the
other on the fluid cap, remove the protective caps from the fluid
outlet fittings.
2.
Ensure that the fluid outlet fitting is tight into the machine.
3.
Ensure that the fluid outlet ports are clean.
4.
Select the end of the glue hose that has the lead assembly with
the male electrical connector (Figure 6).
Connecting
the Hoses
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...