10-31
Section 10 - Part Number List
ValcoMelton
MM125 - D-90 Hot Melt Unit
ITEM
DESCRIPTION
PART #
QTY
1 PANEL;
ELECTRICAL
EQM0693
1
3
PCB ASSY, 12 ZONE GEAR NI-120
151XX680
1
4 STANDOFF;
HEX,
M-F
091XX706
14
5
HEX NUT-M4, SS
798XX299
7
6
*SWITCH, DISCONNECT, FUSIBLE
485XX121
1
7
SHCS M6 X 16 SS
784XX091
4
8
CONTACTOR; 50A, AC1, 3 POLE
160XX290
1
9
SHCS M4 X 12 SS
784XX051
2
12
HEATSINK; SSR, 2 C/W, DIN MT.
100XX001
4
13
*RELAY; SOLID STATE, 600VAC
160XX204
4
14
CONTACTOR; 25A, AC1, 3 POLE
160XX291
1
16
POWER SUPPLY,24VDC 5A
148XX050
1
17
FUSE HOLDER, 2 P 600V TYPE CC
086XX086
3
18 DUCT,30000403
067XX017
152
19
PCB,ASSY,STAND ALONE 4 ZONE
151XX684
1
20 STANDOFF
091XX704
16
21
NUT HEX M3 SS
784XX990
12
22
FUSE HOLDER, 3 P 600V TYPE CC
086XX085
4
23
PCB, ASSY, DUAL VFD +/-15
151XX701
2
24
CABLE ASSY, AC POWER TO 4 ZONE
029XX710
1
25
CABLE ASSY, UTC POWER/COMM
029XX712
1
26
CABLE ASSY, HEATER CONDUCTORS
TAJ0534
2
27
CABLE ASSY, RTD SIGNALS
TAJ0535
2
28 TERMINAL
BLOCK
075XX275
72
29 TERM
BLOCK,
50A,
GRAY
075XX298
7
30
NUT,HEX 3/8-16 SS
798XX679
4
31
FLAT WASHER 3/8 SS
798XX764
4
32 *DIN
MOUNTING
RAIL
091XX277
55
33
BHCS M5 X 10 SS
784XX374
33
35
FUSE, 50A, 600VAC
085XX281
3
36
FUSE; 40A, CLASS J, FAST
085XX280
3
37
FUSE, 30A, 600V, TIME DELAY
085XX199
3
38 FUSE,20
AMP
085XX093
3
39
FUSE, 15 AMP
085XX154
3
40
FUSE, 10A 600V, TIME DELAY
085XX266
6
41
CIRCUIT BRAKER; EARTH LEAKAGE
056XX123
1
42
FUSE HOLDER, 3 P 600V TYPE J
086XX084
1
43
TERM BLOCK, GNC, 50A, YEL/GRN
075XX299
6
45
CABLE ASSY, DC SUPPLY TO 12Z
029XX711
1
47
CABLE ASSY, DC POWER
029XX709
1
48
CABLE ASSY; VFD SIGNAL
029XX698
3
52
END STOP, TERMINAL
075XX273
12
53 END
SECTION,
TERMINAL
075XX274
4
54 *CIRCUIT
SEPARATOR
075XX300
4
55 *JUMPER
BAR
091XX350
2
Electrical Panel Assembly -
Continued
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...