Section 5 – Setup
MM125 - D-90 Hot Melt Unit
Control Panel, Continued
ITEM
NAME
DESCRIPTION
1
System/Ready LED
Illuminates green when the unit reaches ready temperature
2
Warning LED
Illuminates red when the unit enters an alarm condition
3
Setback ON/OFF Key
Put unit into and out of setback mode. This reduces the
temperature to keep the adhesive soft but not molten during
downtime. Yellow LED indicates that the setback mode is initialized.
4
Display Screen
Displays the menu and event screens
5
Clock ON/OFF Key
Turns the clock function on and off. Green LED indicates the clock is
active.
6
Pump ON/OFF Key
Turns the pump on and off. Green LED indicates the pump is active.
7
Standby ON/OFF Key
Puts the unit in and out of standby. Green LED indicates the unit is
on and an orange LED indicates the unit is in standby.
8
Plus Key
Increases the valve of the selected field
9
Right Arrow Key
Move right thru the fields on the screen
10
OK Key
Enters or exits a screen where a selected field can be edited
11
Minus Key
Decreases the valve of the selected field
12
Left Arrow Key
Move left thru the fields on the screen
13
Pump Menu Key
Displays the pump group screens
14
Setup Menu Key
Displays the setup group screens
15
Temperature Menu Key
Displays the temperature group screens
16 Hose
LED
Illuminates green when the hose zone is heating and red when the
zone is in alarm.
17 Gun
LED
Illuminates green when the gun zone is heating and red when the
zone is in alarm.
18 Tank
LED
Illuminates green when the collector zone is heating and red when
the zone is in alarm.
19 Grid
LED
Illuminates green when the grid zone is heating and red when the
zone is in alarm.
20
Pump Manifold LED
Illuminates green when the manifold zone is heating and red when
the zone is in alarm.
21
Internal Low Level LED
Always on unless low level occurs on the internal level control input
22
External Low Level LED
Always on unless low level occurs on the external level control input
23 Tank
Inlet
Filter
Illuminates green when the tank inlet filter block (optional) zone is
heating, and red when the zone is in alarm.
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...