5-33
Valco Cincinnati, Inc.
Section 5 – Setup
MM125 - D-90 Hot Melt Unit
The Sequential Start function allows the hoses and the valves (guns) to begin
heating after the upper platen (referred to as the Tank, below) reaches a
specified temperature offset below the setpoint temperature. This feature is
used to reduce adhesive degradation caused from heating adhesive in the
hoses and valves for long periods while waiting for the tank to reach
temperature.
The sequential start range is 0°F to 450°F (0°C to 250°C). The default factory
setting is OFF.
This parameter can be accessed in Password Level 2 or higher.
Sequential Start –
Hose
Startup Setup