5-16
Valco Cincinnati, Inc.
Section 5 – Setup
MM125 - D-90 Hot Melt Unit
Ready Delay
Time
When the Ready Delay Time is used, the System Ready LED will illuminate a
preset time after all of the zones reach their respective temperature setpoints
minus the System Ready Temperature Offset. This feature allows the
adhesive in the system to heat for an additional period of time before the
pump motor is enabled.
Once the zones have reached the System Ready Temperature, the time
remaining before the system is ready is displayed on the status bar at the
bottom of the screen.
The ready delay range is 1 minute to 120 minutes. The default factory setting
is ON at 30 minutes
ON at 30 minutes
ON at 30 minutes
ON at 30 minutes
ON at 30 minutes.
To prolong the life of the seal in the pump, this default time of 15 minutes
should not be reduced.
This parameter can be accessed in Password Level 2 or higher (see
Appendix A - Password Levels).
C O N T I N U E D N E X T P A G E
Summary of Contents for D-90
Page 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Page 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Page 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Page 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Page 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Page 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Page 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Page 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...