Chapter 13: Alarm and event setup
TruVision NVR 22 (SP) User Manual
121
2. Select
Disable Actions
for the desired alarm panel connection. Three alarm panels
can be linked to the recorder. You can enable Disable Actions for each panel.
Make sure that you also set up the other parameters for the alarm panel. See
“Intrusion integration alarm reporting” on page 111 for further information.
3. Click
Apply
to save the changes.
4. When the alarm panel sends a SIA/XSIA event for disarming (OP message), the
recorder will not execute the actions anymore for motion detection and VCA or for
alarms (alarm inputs or intrusion panel events).
Note
: the actions that are set-up for the disarming event will also no longer be
executed. This is a known limitation.
To define the recording behavior when Disable Actions is used:
1. From the menu toolbar, click
Device Management
>
General Settings
.
2. Select one of the options for
Recording Behavior for Disable Actions
. The
options are:
No influence on recording
: Disable Actions will have no influence on the
recordings. Recording of all cameras will continue as scheduled.
Disable event/alarm recordings
: Disable Actions will stop the scheduled
recordings for events (motion, VCA) and alarms (alarm inputs, intrusion panel
alarms). Cameras that are scheduled for continuous recording will not stop the
recording.
Disable all recordings
: Disable Actions will stop all recordings for all cameras,
regardless of the schedule or recording type.
3. Click
Apply
to save the changes.