Chapter 13: Alarm and event setup
112
TruVision NVR 22 (SP) User Manual
Intrusion Alarm_KA (Technical alarm (High
temperature)
Disarming Panel Alarm
Intrusion Alarm_MA (Medical alarm)
Intrusion Alarm_HV (Hold-up verified)
Intrusion Alarm_PA (Panic alarm
Intrusion Alarm_BV (Burglary verified)
Intrusion Alarm_QA (Emergency alarm)
A heartbeat alarm
In the intrusion panel, set up the recorder as a normal monitoring station. Use OH
version 3 so that the data format is understood by the recorder.
To set up an alarm panel in the recorder:
1. From the menu toolbar, click
Alarm & Event Setup
>
Intrusion Panel Setup
.
2. In the
Intrusion Panel Setup
window, enter the required settings.
Option
Description
Set up the intrusion panel connection parameters:
1.
Enable Intrusion Panel
Connection
Select this check box to enable the intrusion panel
connection.
2.
Select Intrusion Panel
Select which panel you want to set-up. Up to three panels can
be set up.
3.
Name Intrusion Panel
Enter a name for the panel.
4.
Number of Zones
Up to 32 panel zones can report to the recorder. The number
cannot be increased but you can allocate a different ID for
each zone under the “Intrusion Zone Setup” menu.
5.
IP Address Intrusion Panel
Enter the panel’s IP address. The IP address must be in the
same LAN as the recorder.
6.
Server Port
Enter the port that is used to report the events. Default is
9999.