TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix A - Command Set Summary Page 82
atpc_step
SYNTAX
atpc_step <range>
where range = 1-5dB
DEFAULT VALUE
1dB
DESCRIPTION
atpc step size controls the Apex power change size during
ATPC operation. The transmit power is changed in step
size on the Apex, unless the maxatcpower or 0 is
reached.
EXAMPLE
Set the atpc step size to 2
(trango-config)# atpc_step 2
ATPC step size: 2 dB
SUCCESS
RELATED
atpc, atpc_max_power
ber
SYNTAX
ber <duration>
Duration = 1-99sec
DEFAULT VALUE
Duration = 1
DESCRIPTION
ber command is similar to the ”linktest” with internal data
source ONLY. It can be used to test the current link
status and can be used to monitor the link, based on the
specified duration. CLI prompt will not be accessible while
linktest is running
The ber shows the following in the output
Lock: Radio Lock Status
1: if all modem locks are locked
0: if any lock is unlocked
RSSI: The current RSSI value
MSE: The current MSE value
BER : The instantaneous BER value (1sec interval)
Txprofile: The current Tx modulation