![Trango Systems TrangoLINK APEX 18 User Manual Download Page 120](http://html1.mh-extra.com/html/trango-systems/trangolink-apex-18/trangolink-apex-18_user-manual_1150515120.webp)
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix B - Specifications
Page 118
MECHANICAL & ENVIRONMENTAL
Enclosure
Cast Aluminum with RSSI window
Indicators
2-digit LED “in dBm” RSSI indicator for alignment
Dimensions
12 × 12 × 6.8 inches (height × width × length)
Weight
18 lbs
Temperature Range
-40° to 122° F (-40° to +50° C)
Humidity
100% condensing
Interfaces
1 GigaEthernet port, RJ45 (10/100/1000 BaseT)
1 Fiber Optic port (SFP Module required)
1 Ethernet management port, RJ45 (10/100 BaseT)
Power connector
Power-over-Ethernet / 2 pin Molex connector
Redundancy (1+1)
6 pin circular
Antenna Connector
Optional waveguide adapter: WR42 / UBR 220
* Based on purchasable Option Key. Contact sales for more information.
Interface Specifications
Physical
Interface
Bit rate
Impedance
Line Code
Standard
Jitter transfer and jitter
tolerance requirement
Compliance
Fiber
MM
Optical 1Gb/s
N/A Multi
Mode
IEEE
802.3
IEEE 802.3
Fiber
SM
Optical 1Gb/s N/A
Single
Mode IEEE
802.3
IEEE 802.3
10 Base-T
Electrical 10
Mb/s
100 Ohm,
balanced
Manchester
4B/5B
IEEE
802.3
IEEE 802.3
100 Base-T
Electrical 100
Mb/s
100 Ohm,
balanced
Manchester
4B/5B
IEEE
802.3
IEEE 802.3
1000 Base-T Electrical 1 Gb/s
100 Ohm,
balanced
Manchester
4B/5B
IEEE
802.3
IEEE 802.3