TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix A - Command Set Summary Page 114
DESCRIPTION
Uptime is used to display how long the system has been
running, since the last reboot/power cycle.
It shows the current time and uptime.
EXAMPLE
To display current uptime
(trango-config)# uptime
20:45:58 up 1:49, load average
RELATED
Date
utype
SYNTAX
Utype <standby>
DEFAULT VALUE
Main
DESCRIPTION
Utype command identifies the current system role.
The valid type in the current release is main. Only the
active unit may use this command to switch the role type.
The command is prohibited when the standby unit is not in
a good condition.
EXAMPLE
To display current system type
(trango-config)# utype
utype: main
To switch to standby role:
(trango-config)# utype standby
utype: main
RELATED
failover, sync_state, sync
version
SYNTAX
Version
DEFAULT VALUE
N/A