![Trango Systems TrangoLINK APEX 18 User Manual Download Page 54](http://html1.mh-extra.com/html/trango-systems/trangolink-apex-18/trangolink-apex-18_user-manual_1150515054.webp)
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 4 - Deployment & Installation Page 52
Figure 26:
Ethernet Cap Installation
Secondly, Terminate the Cat5/6 cable to a RJ-45 connector.
Finally, connect the RJ-45 connector into the Apex radio and properly orientate the
Ethernet cap over the RJ-45 connector as shown in Figure 27.
Figure 27:
Complete Ethernet Cap Installation
To properly weatherize the Fiber cable and direct DC power first remove the fiber plate
and silicone seal from the unit and pass the Fiber and power cables through the fiber
plate as shown in Figure 28: The silicone seal has a slit in it to slide the cables through
after termination of the cables. Please note that the Fiber plate must be connected to
properly installed conduit to ensure no moisture enters the Apex unit.
!
IT IS IMPORTANT THAT THE ORIENTATION IS CORRECTTO PREVENT WATER
INTRUSION