TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Chapter 3 - Configuration
Page 34
IP Configuration
IP Address:
The IP address assigned to the Unit.
Subnet Mask:
The subnet mask assigned to the Unit.
Gateway:
The gateway assigned to the Unit.
SNMP Trap IP 1:
The IP address of the device that will receive SNMP traps.
SNMP Trap IP 2:
The IP address of the device that will receive SNMP traps.
System Configuration
ACM (Adaptive Code Modulation):
ACM will allow the unit to adjust modulation
seamlessly as the RF signal quality degrades and improves. If this feature is enabled
and modulation decreases, there will be a noticeable reduction in link throughput based
on modulation. The modulation change is hitless for this feature.
ATPC (Automatic Transmit Power Control):
ATPC enabled will allow the link
elements to automatically adjust the output power of the ODU’s to achieve the Target
RSSI. This feature mitigates the effects of flat fading across the link.
Failover:
Enable or disabled 1+1 protection.
IBM:
Enable or disable In-Band Management.
RPS:
Enable or disable Rapid Port Shutdown.
Smart Mode:
Enable or disable Smart Mode feature.
SNMP Trap:
Enable or disable the sending of SNMP traps. This must be enabled to
have the unit send SNMP traps.
Tftpd:
Enable or disable Trivial File Transfer Protocol Daemon. This must be enabled
to upload new firmware images.
Alignment:
Enable or disable alignment mode. Increases refresh rate of LED panel.
Default Opmode:
Operation mode of the radio after a power cycle or reboot. Upon
startup the unit will go into OPMODE “on” if Default Opmode is ENABLED. When the
radio enters Opmode "on" it will be transmitting. When the radio enters Opmode "off"
the radio is not transmitting, but can be accessed via the Ethernet port.