TrangoLINK APEX
18GHz
Point-to-Point Microwave
Wireless Ethernet Bridge
High-Capacity Backhaul Network
User Manual
September 2008
Revision 1.0
Page 1: ...TrangoLINK APEX 18GHz Point to Point Microwave Wireless Ethernet Bridge High Capacity Backhaul Network User Manual September 2008 Revision 1 0...
Page 2: ......
Page 3: ...Opmode Concept 16 Mean Square Error Concept 17 Max Power Input 17 ACM Adaptive Code Modulation 18 ATPC TargetRSSI 19 ATPC Max Power Step Size 19 Port Mapping 802 1q Port Priority 802 1p 20 Class of Se...
Page 4: ...installation 44 SFP Installation 45 Direct DC power connection 45 Polarization 46 1 1 Coupler Installation 47 Polarization of 1 1 Coupler 50 Grounding 51 Weather Proofing Cabling 51 Antenna Alignment...
Page 5: ...tpc_max_power 81 atpc_step 82 ber 82 bootimage 83 cos 84 config 85 date 86 debug 87 default_opmode 87 exit 88 failover 88 freq 89 help 90 httpd 90 ibm 91 ipconfig 92 datapattern 93 license 93 linktest...
Page 6: ...l Rate 119 40 MHz channel 35 42 Symbol Rate 120 30 MHz channel 24 6 Symbol Rate 121 20 MHz channel 17 42 Symbol Rate 122 10 MHz channel 8 32 Symbol Rate 123 FCC Requirement of Frequency Spacing 124 10...
Page 7: ...10 Settings Web Page 32 Figure 11 Statistics Web Page 36 Figure 12 Password Web Page 38 Figure 13 Apex Mounting Assembly 43 Figure 14 Waveguide Adapter Installation 44 Figure 15 SFP Module Installatio...
Page 8: ...ure 28 Fiber Plate Installation 53 Figure 29 Complete Fiber Plate Installation conduit not pictured 53 Figure 30 Windows Start Telnet 55 Figure 31 Verify Firmware Upgrade 58 Figure 32 Serial Number Lo...
Page 9: ...er Manual Rev 1 0 Section Tables Page 7 Tables Table 1 TrangoLINK APEX 18 Part numbers 8 Table 2 MSE Values 17 Table 3 Max Power Input 18 Table 4 ACM Threshold Table 19 Table 5 Default Login Passwords...
Page 10: ...x APEX18 KEY 1 Software Key to Allow Throughputs up to 200Mbps APEX18 KEY 2 Software Key to Allow Throughputs up to 370Mbps Table 1 TrangoLINK APEX 18 Part numbers Emission Designators 10M0D7W for 10...
Page 11: ...TrangoLINK Apex 18 User Manual Rev 1 0 Section Preface Page 9...
Page 12: ...TrangoLINK Apex 18 User Manual Rev 1 0 Section Chapter 1 Overview Page 10 Chapter 1 Overview About this Chapter This chapter introduces the TrangoLINK APEX system features and its components...
Page 13: ...APEX is a Frequency Division Duplex FDD radio which provides low latency of less than 150 s over 1 million packets per second and up to 730 Mbps of data The TrangoLINK APEX uses VLAN and QoS prioritiz...
Page 14: ...TrangoLINK Apex 18 User Manual Rev 1 0 Section Chapter 1 Overview Page 12 Location of Serial Number Figure 2 Side of Radio Shows where MAC address can be found Apex Apex...
Page 15: ...so be connected through this port Management Port 10 100 Out of Band Management port allows for PoE as well as management No data pass through is allowed on this port RSSI Digital Display RSSI value o...
Page 16: ...will be covered in this chapter Connection and Power Basic Configuration Concepts Management It is recommended that you first provision and test the radios on the bench before deploying them in the f...
Page 17: ...Connect Ethernet cable between the Apex unit and the POE unit Power over Ethernet can be through either the data or management ports Alternately there is a 2 pin MOLEX connector under the fiber cover...
Page 18: ...ed from your sales manager Settings and connection steps are found later in this chapter Basic Concepts The TrangoLINK APEX 18 can be configured using either the Command Line Interface CLI or the Web...
Page 19: ...that are improperly constructed path degradations such as multipath or Fresnel zone encroachment Interference may not only come from other transmitters on the tower but also from high power transmitte...
Page 20: ...is an on off command Once ACM is enabled and link is degraded to the MSE threshold specified the radio will shift down in modulation and speed based on the setting of the ACM table Table 4 Profile Mod...
Page 21: ...setting Once enabled ATPC will adjust the power of the remote side based on the local TargetRSSI setting If the RSSI value is lower than the TargetRSSI setting of the local radio the remote radio will...
Page 22: ...BY DEFAULT THROUGH THE SMART_MODE COMMAND SHOULD YOUR NETWORK REQUIRE Q IN Q OR OTHER UNIQUE PROTOCOL YOU MAY NEED TO DISABLE SMART_MODE IN BAND MANAGEMENT WILL NOT WORK WITH SMART_MODE DISABLED Clas...
Page 23: ...ace To access the Browser interface simply open your web browser and enter the IP address of the radio Figure 6 Figure 6 HTTP Login A login window will pop up requiring the user to enter username and...
Page 24: ...all of the hotlinks to the following pages System Information Page Sysinfo Shows most of the basic configuration parameters of the radio It is the first page shown after login Settings Page The essent...
Page 25: ...Type in the login and password and press enter To terminate a CLI session Telnet or Console simply close the session window There is no exit or quit command This is an intentional security feature The...
Page 26: ...mand being typed by pressing tab key If a command is partially typed followed immediately by a it will display all related commands Example trango config t targetrssi Displays target rssi value temp D...
Page 27: ...angoLINK Apex 18 User Manual Rev 1 0 Section Chapter 2 Getting Started Page 25 If the password is lost and you have been locked out of the unit contact Trango Broadband Technical Support for assistanc...
Page 28: ...ing the Browser HTTP Interface This section addresses the basic steps in establishing a link in the lab environment Trango strongly recommends that that you read this manual to gain an understanding a...
Page 29: ...stem Information The TrangoLINK APEX 18 has 4 main web pages The Sysinfo page is a read only page where the current configuration of the unit can been seen The Sysinfo page consists of 4 sections the...
Page 30: ...mode Frequency Displays the Transmit and Receive Frequency of the radio in MHz Power Transmit power of the unit in dBm Please note that there is no internal checking of maximum power Please check the...
Page 31: ...ailover When Failover settings is o Disabled Off The setting has no effect o Enabled On 1 1 failover is enabled and the Status LED on the IDU will start to blink Failover needs to be enabled on both s...
Page 32: ...o Disabled Off There is no internal VLan port mapping o Enabled On Internal VLan port mapping between GE1 and SFP ports keep traffic separate Smart Mode must be enabled to support IBM SNMP Trap Simple...
Page 33: ...l of the unit is shown Serial ID The unique serial ID of the unit is shown ETH0 MAC The Ethernet Media Access Control Address of the management port of the unit Required for license upgrade keys ETH1...
Page 34: ...uration and System Configuration Figure 10 Settings Web Page Radio Configuration System Model Displays the current system model of the unit TX Frequency Set the Center Frequency in accordance with the...
Page 35: ...rangoLINK APEX is shipped with default values Speed 16 QAM and 10 MHz bandwidth which protect the user from inadvertently violating FCC constraints ACM Disabled When the user enables the ACM feature t...
Page 36: ...d will allow the link elements to automatically adjust the output power of the ODU s to achieve the Target RSSI This feature mitigates the effects of flat fading across the link Failover Enable or dis...
Page 37: ...in the product design Ethernet Configuration Port Link The option of enabling or disabling the specified port Auto Nego Enable or disable auto negotiation of the specified port Pause Frame Enable or d...
Page 38: ...tion will also provides the RSSI MSE BER Radio Temp Modulation ACM Profile and if the link has lock Link Status The Link status section provides modem lock and pll information This information is eith...
Page 39: ...or setting selection Pause Frame The Pause frame can be either ON or OFF Duplex The Duplex setting is either Half or Full Priority The Priority ranges between 0 and 7 Speed Displays either 10 100 or 1...
Page 40: ...ckets received and transmitted Ethernet Drop packets The Total number of received Ethernet packets that were dropped Total Drop Packets The total number of packets that were dropped Port Utilization C...
Page 41: ...r for the unit to transmit after a reboot Save and Reboot o The save is needed so that setting changes are persistent through a reboot A reboot is required for settings to take full effect If these pa...
Page 42: ...R is calculated on the RF link The BER is displayed in 0 00E 00 format and measures the number of uncorrected bit errors divided by the number of bits transmitted The BER value displayed in the linkte...
Page 43: ...18 User Manual Rev 1 0 Section Chapter 3 Configuration Page 41 3 1 42 00 dBm 33 05 dBm 0 00E 00 QAM256 QAM256 4 1 42 00 dBm 32 86 dBm 0 00E 00 QAM256 QAM256 5 1 42 00 dBm 33 00 dBm 0 00E 00 QAM256 QAM...
Page 44: ...lation About this Chapter Once you are familiar with the basic operation of the radios you are ready for deployment in the field The deployment process consists of the following steps Mounting Hardwar...
Page 45: ...ase refer to the antenna installation instructions for proper installation of the antenna The unit can be secured to the tower pole with high strength cable strung through the clasp hole to discourage...
Page 46: ...he waveguide port on the Apex unit Next lubricate the O Ring with the supplied silicone lubricant and place the O Ring into the grove on the radio unit Place the Waveguide Adapter into the bore on the...
Page 47: ...ed later in this chapter and you can now use your Gigabit Fiber connection Figure 15 SFP Module Installation Direct DC power connection If you wish to use a direct DC connection to power up your Trang...
Page 48: ...olarity from vertical to horizontal is easy Simply unlatch the Apex Unit from the antenna and rotate counter clockwise and reattach the Apex Unit to the antenna Figure 17 shows a unit mounted with ver...
Page 49: ...single antenna The mount has a single couple centered on one side Figure 19 while there are 2 evenly spaced on the second side Figure 19 1 1 Coupler To install the mount simply attach the single sided...
Page 50: ...on for the 1 1 mount is determined by the transition between the mount and the antenna The Apex radios needs to be mounted in the H Pol position on the 1 1 mount as the coupler determines polarity Ple...
Page 51: ...1 0 Section Chapter 4 Deployment Installation Page 49 Figure 22 1 1 Apex Mounting THE APEX UNITS NEED TO BE MOUNTED IN THE SAME POSITIONS TO THE 1 1 MOUNT POLARAZATION IS DETERMINED BY THE COUPLER BET...
Page 52: ...must be replaced with a horizontal coupler Figure 23 This coupler has a twist transition so it will look slightly different than the coupler that connects to the Apex The 1 1 coupler also has 2 sligh...
Page 53: ...e 25 POE Ground Screw IF THE ANTENNA SUPPORT STRUCTURE IS NOT EARTH GROUNDED THROUGH A LOW RESISTANCE HIGH CURRENT PATH DO NOT PROCEED WITH THE INSTALLATION Weather Proofing Cabling It is important to...
Page 54: ...27 Complete Ethernet Cap Installation To properly weatherize the Fiber cable and direct DC power first remove the fiber plate and silicone seal from the unit and pass the Fiber and power cables throug...
Page 55: ...connector Finally re seat the silicone seal into the Apex unit and screw the Fiber plate back to the unit as shown in Figure 29 Figure 29 Complete Fiber Plate Installation conduit not pictured IT IS...
Page 56: ...the other side to improve the link Alignment can be done using the Digital RSSI panel on the Apex Unit Antenna Alignment Procedure 1 Ensure that both sides of the link are configured correctly 2 Conn...
Page 57: ...rmware File idu_pic_xxyy System Modem Firmware File idu_modem bin Before beginning the upgrade procedure be certain that all sometimes it will be a subset of the above files of these files have been d...
Page 58: ...d on tftpd on SUCCESS trango config 4 Open a MS DOS prompt window and access the directory that you extracted the firmware files C CD Firmware C Firmware 5 Using windows TFTP command line tool we will...
Page 59: ...t required to issue reboot after each upgrade A single reboot can be issued after all the images have been successfully upgraded to reduce the downtime trango config reboot The upgrade time varies dep...
Page 60: ...x 18 User Manual Rev 1 0 Section Chapter 4 Deployment Installation Page 58 FPGA version 01270608 OS version 2p6r14b3D07230801 FW version 1p0r0D072308 PIC version 214 RFM version 1C Figure 31 Verify Fi...
Page 61: ...onsole we will focus management via SNMP in this chapter Please review Chapter 3 for HTTP configuration and Appendix A for CLI configuration commands and procedures Understanding and familiarization o...
Page 62: ...a few of the more commonly used SNMP objects in the TrangoLINK APEX 18 system If you do not have a copy of the MIB files for your current firmware version please contact Trango Technical Support to o...
Page 63: ...e trap is triggered when the Backup unit has taken over trapModemLock This trap will inform you when there is a change to the link lock trapDownShift This trap will inform you when the modulation of h...
Page 64: ...ubleshooting Page 62 Chapter 6 Troubleshooting About this Chapter In this chapter we will cover some of the more common steps to take when encountering difficulties with the TrangoLINK APEX 18 No Link...
Page 65: ...targetrssi is set correctly so that the link doesn t decrease power to the point of losing the link Check the power setting on both sides of the link Check to make sure Loopback is disabled Antennas a...
Page 66: ...Errors on GigE port Ensure there is no duplex mismatch The TrangoLINK APEX can be configured for Auto negotiate 1000 Full duplex 1000 Half duplex 100 Full duplex 100 Half duplex 10 Full duplex and 10...
Page 67: ...open an HTTP browser session Check your cable connections Ensure proper cable is being used cross over vs straight through cable Check PC s subnet to make sure it is routable to the radio s IP address...
Page 68: ...TrangoLINK Apex 18 User Manual Rev 1 0 Section Chapter 6 Troubleshooting Page 66 Figure 32 Serial Number Location Apex Apex...
Page 69: ...8 User Manual Rev 1 0 Section Chapter 7 Bench Testing Page 67 Chapter 7 Bench Testing About this Chapter In this chapter we will cover the basic tips in setting up the equipment for bench testing the...
Page 70: ...oying the equipment Bench testing provides the user with a baseline of results and helps ensures that the equipment operates according to specification before deployment It is a preventive measure tha...
Page 71: ...SSI is less than 25dBm 30 to 35 is optimal 6 Perform throughput testing by connecting PC s to the data ports and passing FTP or other IP traffic across the link 7 Confirm proper SNMP setup by enabling...
Page 72: ...pex 18 User Manual Rev 1 0 Section Chapter 7 Bench Testing Page 70 If you experience any problems during the setup or testing process please contact Trango Technical Support at 858 391 0010 for furthe...
Page 73: ...list of commands that begin with that string Del or BS Erases the character to the left of the cursor Return At the command line pressing the Return key performs the function of processing a command...
Page 74: ...data source for data pattern date Display time of Day default_opmode Display default opmode status failover Display failover mode status freq Display RF Tx Rx frequency help Display help command httpd...
Page 75: ...password and after successful authentication users enters the config mode All configuration settings can be changed here All the commands entered without any parameters returns the current configured...
Page 76: ...freq 17705 19695 0 this is exception to the valid range help N A N A httpd on off On ibm enable on off off ip ip address 172 16 1 1 vlanid 1 4090 100 ipconfig ip address netmask gateway ip 192 168 100...
Page 77: ...e pause maxrate priority speed auto negotiate on off On duplex half full Full enable on off on for both GigE copper and fiber ingress_rate 0 1000 Mbps 0 0 1000Mbps pause on off Off priority 0 3 0 spee...
Page 78: ...odem fifo pll port all clear N A sysinfo 0 6 0 if command executed without any param syslog clear N A targetrssi 88 25 40 temp N A N A telnetd on off On tftpd on off Off param min max value action Def...
Page 79: ...d View mode share the same password and the password can be changed from the debug node only Command List in Debug Mode Cli Used to Enter the CLI trango view node Exit Logout of the system Help Displa...
Page 80: ...rent MSE value And predefined MSE degrade and imrove thresholds ACM is not symmetric and each end can have different profiles at a given time depending upon the MSE values on each end acm mod is used...
Page 81: ...mprove Next Degrade Next 0 QAM128 32 1 0 27 2 1 1 QAM64 29 2 0 24 3 2 2 QAM32 26 3 1 21 3 3 3 QAM16 23 3 2 18 5 4 4 QPSK 20 3 3 17 1 4 QAM64 Profile Modulation Improve Next Degrade Next 0 QAM64 29 2 0...
Page 82: ...ration EXAMPLE Turn on the alignment_mode trango config alignment_mode on alignment_mode on Check current alignment mode setting trango config alignment_mode alignment mode on RELATED rssiled targetrs...
Page 83: ...ig atpc ATPC on RELATED atpc_max_power atpc_step_size targetrssi power atpc_max_power SYNTAX atpc_max_power 0 20 DEFAULT VALUE Default 17 DESCRIPTION This command is used to set the upper limit on tra...
Page 84: ...UCCESS RELATED atpc atpc_max_power ber SYNTAX ber duration Duration 1 99sec DEFAULT VALUE Duration 1 DESCRIPTION ber command is similar to the linktest with internal data source ONLY It can be used to...
Page 85: ...d in the flash The Apex radio is capable of storing 2 complete set of images in the flash See version command A reboot of the radio is required to load the new image after upgrade If upgrading multipl...
Page 86: ...tion and the reboot trango config reboot RELATED version tftpd reboot cos SYNTAX Cos priority queue DEFAULT VALUE Default Mappings are as shown below Priority 0 COS Queue 0 Priority 1 COS Queue 0 Prio...
Page 87: ...sed to view remove and transfer current system configuration file Export The option allows the user to create a ASCII file config txt of the current system configuration which can then be tftp from th...
Page 88: ...17920 RX_FREQ 19480 RX_FREQUENCY 0 0 CABLELOSS_140 0 0 CABLELOSS_315 0 0 CABLELOSS_915 0 0 POWER 6 0 RELATED Tftpd reboot save date SYNTAX date year month date hour min year 0 99 month 1 12 date 1 31...
Page 89: ...to debug prompt trango config debug debug RELATED cli config exit default_opmode SYNTAX Default_opmode on off DEFAULT VALUE Off DESCRIPTION Default opmode command is used to set the default operationa...
Page 90: ...stem debug exit RELATED clii config failover SYNTAX failover on off DEFAULT VALUE Off DESCRIPTION This command is to enable failover 1 1 feature and needs to be enabled on both the units After enablin...
Page 91: ...active unit is powered off and the data ports disabled The failed unit is not rebooted and can be used to diagnose the problem Appropriate traps are sent in the case of Active failover Standby detecti...
Page 92: ...etting trango config freq TX freq 19480 RX freq 17920 RELATED opmode help SYNTAX DEFAULT VALUE N A DESCRIPTION Typing the command will display the list of commands in the current node with a one line...
Page 93: ...opper 1 fiber DEFAULT VALUE Enable on Id 1 IP 10 10 10 1 DESCRIPTION This command is used to configure the In Band Management IBM channel to manage the system Both IBM and the Out of Band Management O...
Page 94: ...100 100 DESCRIPTION This command is used to set IP address subnet mask and default gateway for the management port of the system All three parameter must be present The system MAC address can be disp...
Page 95: ...external during normal mode of operation otherwise no user data from GigE or the T1 ports will be transmitted EXAMPLE To set data pattern source trango config datapattern external Data pattern Externa...
Page 96: ...t command is used to test the current link status and can be used to monitor the link based on the specified duration CLI prompt will not be accessible while linktest is running The linktest shows the...
Page 97: ...ls are set the logs can be monitored through the syslog command E g Setting the loglevel to 2 will only log Status Stats The loglevel needs to be set to loglevel 0 1 2 to monitor all logs EXAMPLE To s...
Page 98: ...ack Loopback Mode if RELATED opmode datapattern model SYNTAX Model DEFAULT VALUE N A DESCRIPTION Display system model and serial numbers EXAMPLE To display the current model serial of the system trang...
Page 99: ...r on the system Opmode settings are not persistent across reboot See default_opmode command Freq needs to be set before opmode can be urned ON EXAMPLE Set opmode on trango config opmode on opmode on R...
Page 100: ...2 pause on off port eth ge1 ge2 priority 0 3 port eth ge1 ge2 speed 10 100 1000 DEFAULT VALUE For GigE copper and fiber Ports the default settings are Autonegotiate ON Duplex Full Enable ON Rate 1000M...
Page 101: ...dent upon the modulation See datasheet When the user sets the power to 20 for QAM256 it is internally adjusted to 17 Max for QAM256 The user cannot change power when ATPC is ON EXAMPLE Set the transmi...
Page 102: ...ed name info related with the Radio EXAMPLE Set remark to TranoLINK Apex trango config remark TrangoLINK Apex Remark TrangoLINK Apex SUCCESS RELATED N A remove SYNTAX Remove config DEFAULT VALUE N A D...
Page 103: ...eboot EXAMPLE Restore factory default settings trango config reset Default setting restored Issue reboot command for the default to take effect SUCCESS RELATED Reboot rps_enable SYNTAX rps_enable on o...
Page 104: ...monitor the received signal level It is used to monitor the link based on the specified duration CLI prompt will not be accessible while rssi command is running RSSI value will display LO if below 90...
Page 105: ...system settings are persistent across reboot power cycles Save command should be used after system setting change Otherwise it will be lost after reboot Multiple changes can be saved by one save comma...
Page 106: ...E To display the currently configured passwords on the system trango config show passwords CLI View node trango CLI Config node trango SNMP Read community public SNMP Write community private Web inter...
Page 107: ...N and trapip should be configured correctly EXAMPLE Set snmptrap ON trango config snmptrap on snmptrap on SUCCESS RELATED snmpd trapip ipconfig speed SYNTAX Speed channel_bw modulation Channel_bw 0 5...
Page 108: ...ion 256QAM speed 312 20 bpf 56 fcc_bw 80 SUCCESS RELATED Freq license status SYNTAX Status modem pll port all clear DEFAULT VALUE N A DESCRIPTION Status command is used to display the current status S...
Page 109: ...Status IN OUT Total Data Octets 0 0 Total Data Pkt 0 0 Total Drop Pkt 0 N A Port Rate Mbps 0 0 Port Util percent 0 0 RELATED Sysinfo sysinfo SYNTAX Sysinfo 0 6 0 All 1 Management 2 Radio Config 3 Syst...
Page 110: ...C step size 1 dB ATPC max power 17 0 dBm Target RSSI 40 00 dBm Symbol Rate 46 00 Modulation 128QAM Speed 289 90 Mbps FCC BW 80 3 System Configuration Alignment Mode off ATPC on ACM on Rssiled on Opmod...
Page 111: ...Status sync SYNTAX sync DEFAULT VALUE N A DESCRIPTION This command is allowed only on the active unit to initiate synchronization process with the standby unit On detecting the Standby unit the Activ...
Page 112: ...over sync syslog SYNTAX Syslog clear DEFAULT VALUE N A DESCRIPTION Syslog command is used to display system event log All the configuration changes and errors are logged The system log is a circular b...
Page 113: ...the targetrssi at 45dBm trango config targetrssi 45 target rssi 45 00 dBm SUCCESS RELATED atpc rssi temp SYNTAX temp DEFAULT VALUE N A DESCRIPTION Temp command is used to display the current system t...
Page 114: ...DEFAULT VALUE OFF DESCRIPTION Turn on tftp server Used to transfer software images during upgrades EXAMPLE Enable tftp server trango config tftpd on tftpd on SUCCESS RELATED Bootimage threshold SYNTA...
Page 115: ...80 and action to send a snmptrap trango config threshold 0 min 80 3 min 80 SUCCESS RELATED Snmptrap snmpd trapip trapip SYNTAX Trapip manager 1 2 ipv4 address DEFAULT VALUE 0 0 0 0 DESCRIPTION Trapip...
Page 116: ...RELATED Date utype SYNTAX Utype standby DEFAULT VALUE Main DESCRIPTION Utype command identifies the current system role The valid type in the current release is main Only the active unit may use this...
Page 117: ...radio The system is capable of have multiple images EXAMPLE To display the current previous software version FPGA version 02150708 OS version 2p6r14b3D07250801 FW version 1p0r0D072508 PIC version 215...
Page 118: ...hz RF Power Output max per modulation QPSK 16QAM 32QAM 64QAM 128QAM 256QAM 20 dbm 20 dbm 20 dbm 19 dbm 18 dbm 17 dbm Modulation Format Selectable from QPSK 16QAM 32QAM 64QAM 128QAM 256QAM Receiver Sen...
Page 119: ...7 142 Mbps 74 165 Mbps 71 188 Mbps 68 40 MHz 64 Mbps 86 128 Mbps 79 159 Mbps 75 194 Mbps 73 226 Mbps 69 258 Mbps 67 50 MHz 77 Mbps 84 156 Mbps 77 195 Mbps 74 236 Mbps 71 275 Mbps 68 314 Mbps 65 56 80...
Page 120: ...rnet 2 pin Molex connector Redundancy 1 1 6 pin circular Antenna Connector Optional waveguide adapter WR42 UBR 220 Based on purchasable Option Key Contact sales for more information Interface Specific...
Page 121: ...119 T I Curves The Interference test measures the performance of the receiver under co channel and adjacent channel interferers 80 MHz channel 46 Symbol Rate 46 QPSK Like Interference T I 40 35 30 25...
Page 122: ...120 40 MHz channel 35 42 Symbol Rate 35 42 QAM 256 Like Interference T I 30 20 10 0 10 20 30 40 0 20 40 60 80 100 120 Carrier Separation MHz T I dB T I dB 35 42 QPSK Like Interference T I 40 35 30 25...
Page 123: ...s Page 121 30 MHz channel 24 6 Symbol Rate 24 6 QAM 256 Like Interference T I 30 20 10 0 10 20 30 40 0 20 40 60 80 100 120 Carrier Separation MHz T I dB T I dB 24 6 QPSK Like Interference T I 50 40 30...
Page 124: ...s Page 122 20 MHz channel 17 42 Symbol Rate 17 42 QAM 128 Like Interference T I 30 20 10 0 10 20 30 0 20 40 60 80 100 120 Carrier Separation MHz T I dB T I dB 17 42 QPSK Like Interference T I 50 40 30...
Page 125: ...ons Page 123 10 MHz channel 8 32 Symbol Rate 8 32 QAM 64 Like Interference T I 30 20 10 0 10 20 30 0 20 40 60 80 100 120 Carrier Separation MHz T I dB T I dB 8 32 QPSK Like Interference T I 50 40 30 2...
Page 126: ...receive MHz Receive transmit MHz 1560 MHz Separation 17705 0 19265 0 17715 0 19275 0 17725 0 19285 0 17735 0 19295 0 17745 0 19305 0 17755 0 19315 0 17765 0 19325 0 17775 0 19335 0 17785 0 19345 0 177...
Page 127: ...35 0 19495 0 17945 0 19505 0 17955 0 19515 0 17965 0 19525 0 17975 0 19535 0 17985 0 19545 0 17995 0 19555 0 18005 0 18565 0 18015 0 19575 0 18025 0 19585 0 18035 0 19595 0 18045 0 19605 0 18055 0 196...
Page 128: ...Separation 17710 0 19270 0 17730 0 19290 0 17750 0 19310 0 17770 0 19330 0 17790 0 19350 0 17810 0 19370 0 17830 0 19390 0 17850 0 19410 0 17870 0 19430 0 17890 0 19450 0 17910 0 19470 0 17930 0 19490...
Page 129: ...z Separation 17720 0 19280 0 17760 0 19320 0 17800 0 19360 0 17840 0 19400 0 17880 0 19440 0 17920 0 19480 0 17960 0 19520 0 18000 0 19560 0 18040 0 19600 0 18080 0 19640 0 18120 0 19680 0 80 MHz maxi...
Page 130: ...e cable pin outs for straight through and cross over cables The images below conform to EIA TIA industry standard for 568 A and B IF the first and second pin are orange the cable is 568B If the first...
Page 131: ...Apex Serial Cable Pin out Below are the images depicting the cable pin out for the TrangoLINK Apex serial cable Please note that Trango recommends purchasing this cable directly from Trango to ensure...
Page 132: ...4 1 5454 1 60 1 3 1 sysFPGAPreVer DisplayString RO 0 80 N A 1 3 6 1 4 1 5454 1 60 1 3 2 sysFWPreVer DisplayString RO 0 80 N A 1 3 6 1 4 1 5454 1 60 1 3 3 sysOSPreVer DisplayString RO 0 80 N A 1 3 6 1...
Page 133: ...able 0 Enable 1 Enable 1 1 3 6 1 4 1 5454 1 60 1 15 sysAlignmentMode INTEGER RW 0 OFF 1 ON 0 OFF 1 3 6 1 4 1 5454 1 60 1 16 sysFailover INTEGER RO 0 OFF 1 ON 0 OFF 1 3 6 1 4 1 5454 1 60 1 17 1 sysTrap...
Page 134: ...sACMProfileQPSKEnable INTEGER RW 0 OFF 1 ON 0 OFF 1 3 6 1 4 1 5454 1 60 2 7 2 2 sysACMProfileQAM16Enable INTEGER RW 0 OFF 1 ON 0 OFF 1 3 6 1 4 1 5454 1 60 2 7 2 3 sysACMProfileQAM32Enable INTEGER RW 0...
Page 135: ...fSymrate INTEGER RO 0 RATE8 1 RATE17 2 RATE26 3 RATE35 4 RATE43 5 RATE49 1 1 3 6 1 4 1 5454 1 60 3 4 2 rfModulation INTEGER RW 0 QPSK 1 16Q 2 32Q 3 64Q 4 128Q 5 256Q 0 QPSK 1 3 6 1 4 1 5454 1 60 3 4 3...
Page 136: ...GER RW 0 OFF 1 ON 1 ON 1 3 6 1 4 1 5454 1 60 4 3 1 gigeEth1Status INTEGER RO 0 OFF 1 ON N A 1 3 6 1 4 1 5454 1 60 4 3 2 gigeEth2Status INTEGER RO 0 OFF 1 ON N A 1 3 6 1 4 1 5454 1 60 4 4 1 gigeEth1Spe...
Page 137: ...4 16 1 gigeEth1OutTotalPackets Counter32 RO 0 4294967296 N A 1 3 6 1 4 1 5454 1 60 4 16 2 gigeEth2OutTotalPackets Counter32 RO 0 4294967296 N A 1 3 6 1 4 1 5454 1 60 4 17 1 gigeEth1CRCErrors Counter3...
Page 138: ...rent FER value N A 1 3 6 1 4 1 5454 1 60 6 4 4 1 trapRSSIMinThreshold RO Current RSSI value N A 1 3 6 1 4 1 5454 1 60 6 4 4 2 trapRSSIMaxThreshold RO Current RSSI value N A 1 3 6 1 4 1 5454 1 60 6 4 6...
Page 139: ...TrangoLINK Apex 18 User Manual Rev 1 0 Section Appendix D MIB Page 137 1 3 6 1 4 1 5454 1 60 6 8 trapDownShift RO N A N A 1 3 6 1 4 1 5454 1 60 6 9 trapRapidPortShutdown RO N A N A...
Page 140: ...ex APEX18 Key 2 Software License Key Upgrade to 370Mbps Full Duplex P Supply 1U 48 48 VDC 1U rack mount power supply P Supply DT 48 48 VCD Universal Desktop Power Supply 1 5 A POE APEX 48 Power Over E...
Page 141: ...rward Error Correction FPGA Field Programmable Gate Array FTP File Transfer Protocol GigE Gigabit Ethernet HTTP HyperText Transfer Protocol HTTPD HyperText Transfer Protocol Daemon HTTPS HyperText Tra...
Page 142: ...Jack 45 RS 232 Recommended Standard 232 RSSI Receive Signal Strength Indicator Rx Receive SNMP Simple Network Management Protocol SSH Secure Shell Sysinfo System Information T I Threshold to Interfere...