81
TRAK Machine Tools
Southwestern Industries, Inc.
32240 - Printer and MMS - Installation & Printing Guide
13.
From the LCD screen, go to:
Prepare > Software Tools > A2
/
A4
(depending on what machine you have)
>
Service > Z_Comparison.gcode
Main Menu
Prepare Menu
Software Tools
A4 Folder
Service Folder
14.
The program will automatically start to
move the print head in the programmed
sequence in order to give a dial indicator
reading for each nozzle.
•
The recommended tolerance
between Nozzle 1 & 3 is +/-
0.02mm.
•
The recommended tolerance
between Nozzle 1 & 2 or Nozzle
2 & 3 is +/- 0.01mm.
If the nozzle heights are not within the
tolerances listed above, they will need to be
re-calibrated.
If the nozzles heights are within tolerance,
move on to Calibration Prints
(skip Adjust your Z Nozzle Height)
Adjust your Z Nozzle Height
(if applicable)
:
1.
Leave the Dial Indicator placed underneath
the nozzle that you need to adjust.
2.
Remove the top cover from the printer for
better access to the extruder assembly and
print head.