91
7.9. Area H (Multifunction Output Setting Area)
Multifunction output setting item
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
H-00
Multifunction output terminal (1)
function selection
0: [No
function]
1: Speed
detection
(1)
(speed is equal to the detection setting)
2: Speed
detection
(1)
(speed is more than or equal to the
detection setting)
3: Speed
detection
(1)
(speed is less than or equal to the
detection setting)
4: Speed
detection
(2)
(speed is equal to the detection setting)
5: Speed
detection
(2)
(speed is more than or equal to the
detection setting)
6: Speed
detection
(2)
(speed is less than or equal to the
detection setting)
7: Specified value reached
8: Armature current detection (polarized)
9: Armature current detection
(absolute value)
10: During power failure
11: Overload pre-alarm
12: During retrying
13: During reversing
14: Protection code
15: [No function]
16: In operation
17: [No function]
18: Timer 1 elapsed
19: Timer 2 elapsed
20: Second setting block selected
21: Cooling fan failure
22: External DB (dynamic braking) unit failure
- 7
-
H-01
Multifunction output terminal (2)
function selection
- 1
-
H-02
Multifunction output terminal (3)
function selection
- 0
-
H-03
Multifunction output terminal (4)
function selection
- 8
-
H-04
Multifunction output terminal (5)
function selection
- 2
-
H-05
Multifunction output terminal (6)
function selection
- 3
-
H-06 Speed
detection
(1)
- Maximum speed (A-00) to maximum speed
(A-00)
1 0
r/min
H-07 Speed
detection
(2)
- Maximum speed (A-00) to maximum speed
(A-00)
1 0
r/min
H-08
Speed detection width
0 to 600
1
0
r/min
H-09
Armature current detection (with
polarity)
-205 to 205
1
0
%
H-10
Armature current detection (absolute
value)
0 to 205
1
0
%
H-11
Overload protection pre-alarm
operation level setting
0 to 100
1
50
%
H-12
Maximum speed/voltage reduction rate 50.0 to 100.0
0.1
90.0
%
Multifunction output terminal (1) function selection (H-01) to multifunction output terminal (5) (H-05):
Figure below shows typical connection methods for multifunction output terminals (1) to (2) of [VFC66-Z TB1]
(MO1, MO2). Multifunction output terminals (1) to (2) of [VFC66-Z TB1] (MO1, MO2) are set as an output
terminal block for functions of multifunction output configured at multifunction output terminal (1) function
selection to multifunction output terminal (2) function selection (H-01 to H-02). The multifunction output
terminal is transistor open collector output and requires an external direct current power source when used. In
addition,
the maximum allowable voltage is 24 V, maximum allowable current per terminal is 20 mA
.
Note that multifunction output terminals (3) to (6) ([optional board] (MO3 to 6)) are optional. For details, refer
to the Optional Instruction Manual. For details of multifunction output function, refer to "Multifunction output
terminal function description list" described later.