23
3.3. How to Perform Trial Operation
In the trial operation, perform the trial operation only with the motor first and check that it operates properly.
Only after that, connect it to the unit. This section describes how to perform the trial operation by using the
console panel [SET66-Z].
Preparation/Wiring
Check capacity/voltage to use
Power-on
Check the model/mode of
VF66B (DC motor drive)
Set the speed command,
acceleration/deceleration time, etc.
Operation/Stop
Perform wiring between VF66B (DC motor drive) and power supplies (R/L1, S/L2,
T/L3), outputs (P and N) and motors (A and F), and the ground (
).
<Model> <Mode>
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
Press the [MONI/FNC] key on the console panel
[SET66-Z] to turn on FNC (LED). Set “0. SrEF” (speed
command)/”3. Acc1” (acceleration time), etc. For the
details, refer to Chapter 3 “3.3.1 How to Change the
Motor Speed” and the subsequent sections.
Set motor constant
Select the operation
commanding place
Setting
change
Press the [MONI/FNC] key on the console panel
[SET66-Z] to turn off FNC (LED). When you press the
[START] key, the operation starts with the speed
command (0. SrEF), acceleration time (3. Acc1), etc. as
they were set. When you press the [STOP/RESET] key,
the operation stops.
Set the constant in the parameter to the motors required for operation.
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
Set the operation commanding place for the operation command, speed
command, etc. to the console panel [SET66-Z]. Set as follows.
Area b
*In the default setting (factory default data), they are as follows.
Display Contents
Setting
value
b-09
Command input when coupled
Set to 1 (console)
b-10
Speed command input selection
Set to 0 (interlocked)
b-11
Operation command input selection
Set to 0 (interlocked)
b-12
JOG command input selection
Set to 0 (interlocked)