19
3.2.4. How to Check Monitor Information
With VF66B (DC monitor drive), you can monitor various data, such as the motor speed, current, and
voltage, by the LED display of the console panel [SET66-Z]. Select the item to monitor in the following
steps.
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
When the FNC (LED) on the console panel is turned on, press the [MONI/FNC] key
to turn off the FNC (LED).
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
The currently set monitor item is displayed for about one second.
<The figure on the left shows that the motor speed (SPd) is set as the
monitor item.>
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
About one second later, the display changes to data display of the
currently set monitor item.
<The figure on the left shows that the motor speed (SPd) is “0
[r/min].”>
1 sec later
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
When you press either the [SET], [
↑
], or [
↓
] key, the currently set
monitor item is displayed.
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
When you press either the
[SET] or [
↑
] key while the
monitor item is displayed, the
display switches to the next
monitor item and displays it.
In this case, the display
switches to the speed
command value (SrEF).
r/min
Hz
A
V
FNC
DIR
REV
ALM
RUN
JOG
FNC
RESET
FWD
JOG
START
STOP
REV
MONI
SET
→
When you press the [
↓
] key
while the monitor item is
displayed, the display
switches to the next monitor
item and displays it.
In this case, the display
switches to the protection
history display (trbLE).