117
The following steps show how to adjust the Vdc detection gain (L-00) through Vdc adjustment (S-03).
Press the [MONI/FNC] key to enter the FNC (function selection) mode (LED-FNC is lit).
Select "S-00" using [
↑
][
↓
] keys ("S" starts flashing).
Shift the target digit to the right using the [JOG/
→
] key, and edit the number with [
↑
][
↓
] keys to enter
"1040".
Subsequently confirm it with the [SET] key. If entering any value other than "1040",
is
displayed.
"S-03" is displayed again. Confirm it with the [SET] key.
Using [JOG/
→
][
↑
][
↓
] keys, enter the value measured with a direct-current voltage meter or a tester
connected beforehand. Confirm it with the [SET] key.
Shift the target digit to the right using the [JOG/
→
] key, change the number to "03" with [
↑
][
↓
] keys to
specify "S-03", and confirm it with the [SET] key.
*S-03 (Vdc adjustment)
Vdc detection gain (L-00) is automatically changed if "S-03" is displayed again.
Display the monitor item pressing the [MONI/FNC] key.
ROM Rewrite Enabling Switch
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
S-04
ROM rewrite switch
ROM rewrite is enabled by entering 1040 after
power-on.
- -
-
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
S-05 [No
function]
*1
- -
-
-
Analog Gain/Offset Automatic Adjustment
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
S-06
Analog input (1) adjustment
1: Analog input (1) offset adjustment
Enter a value 1000 times the analog input (1)
voltage (V):
Analog input (1) gain adjustment
- -
-
S-07
Analog output (1) adjustment
1: Analog output (1) offset adjustment
2: Analog output (1) gain adjustment
- -
-
S-08
Analog input (2) adjustment
1: Analog input (2) offset adjustment
Enter a value 1000 times the analog input (2)
voltage (V):
Analog input (2) gain adjustment
- -
-
S-09
Analog output (2) adjustment
1: Analog output (2) offset adjustment
2: Analog output (2) gain adjustment
- -
-
S-10
Analog input (3) adjustment
1: Analog input (3) offset adjustment
Enter a value 1000 times the analog input (3)
voltage (V):
Analog input (3) gain adjustment
- -
-