45
6.16. Area S (Setting Area for Mode Selection and Analog Input/Output Adjustment)
Symbols of Driving ReWrite
: ReWrite is possible, ×: ReWrite is not possible
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
S-00
Special mode selection
1:
VF66B (DC motor drive) initialization
2:
[For special adjustment]*1
3: Clear
protections
4:
[For special adjustment]*1
10 to 15: [No function]
99: VF66B (DC motor drive) initialization [for
special adjustment]
*1
101: Data transfer to SET66EX-Z
*2
102: Data copy from SET66EX-Z (without
area A)
*2
103: Data copy from SET66EX-Z (with area
A)
*2
104: Data comparison with SET66EX-Z
*2
- -
S-01 Cumulative_operation_timer(1)_clear
1:
Clear the Cumulative_operation_timer(1)
-
-
S-02 Cumulative_operation_timer(2)_clear
1:
Clear the Cumulative_operation_timer(2)
-
-
S-03
Vdc adjustment
Vdc value (V): Vdc detection gain adjustment
-
-
×
S-04
ROM rewrite switch
ROM rewrite is enabled by entering 1040 after
power-on.
- -
×
S-05 [No
function]
-
-
-
-
S-06
Analog input (1) adjustment
1: Analog input (1) offset adjustment
Enter a value 1000 times the analog input
(1) voltage (V):
Analog input (1) gain adjustment
- -
×
S-07
Analog output (1) adjustment
1: Analog output (1) offset adjustment
2: Analog output (1) gain adjustment
- -
×
S-08
Analog input (2) adjustment
1: Analog input (2) offset adjustment
Enter a value 1000 times the analog input
(2) voltage (V):
Analog input (2) gain adjustment
- -
×
S-09
Analog output (2) adjustment
1: Analog output (2) offset adjustment
2: Analog output (2) gain adjustment
- -
×
S-10
Analog input (3) adjustment
1: Analog input (3) offset adjustment
Enter a value 1000 times the analog input
(3) voltage (V):
Analog input (3) gain adjustment
- -
×
S-11
Analog output (3) adjustment
1: Analog output (3) offset adjustment
2: Analog output (3) gain adjustment
- -
×
S-12
Analog input (4) adjustment
1: Analog input (4) offset adjustment
Enter a value 1000 times the analog input
(4) voltage (V):
Analog input (4) gain adjustment
- -
×
S-13
Analog output (4) adjustment
1: Analog output (4) offset adjustment
2: Analog output (4) gain adjustment
- -
×
S-14
Analog input (5) adjustment
1: Analog input (5) offset adjustment
Enter a value 1000 times the analog input
(5) voltage (V):
Analog input (5) gain adjustment
- -
×
S-15
Analog output (5) adjustment
1: Analog output (5) offset adjustment
2: Analog output (5) gain adjustment
- -
×
S-16
[For special adjustment]
*1
-
-
* For area S setting, enter 1040 first, then within 60 seconds a selection item must be entered.
*1: Provided for special adjustment. Usually do not set this item.
*2: SET66EX-Z is an external consoled panel which is optional.